An Automated and Precise Approach for the Determination of Azide Residue in Angiotensin II Receptor Blockers Using In Situ Matrix Elimination Ion Chromatography with Switching Strategy

Angiotensin II receptor blockers (ARBs), a critical class of second-generation antihypertensive drugs, require azide intermediates for constructing their biphenyl tetrazole pharmacophore. This synthetic reaction introduces hypertoxicity risks, as residual azides can induce fatal damage even at trace concentrations. The pharmacopoeias of most countries have highlighted the urgency for improved detection paradigms of the control of azides in ARBs. Current ion chromatography (IC) methods face analytical challenges due to matrix interference from organic solvents and incompatibility with hydrophobic ARB ingredients. Herein, an in situ matrix elimination ion chromatography methodology was established for the sensitive detection of trace azides in angiotensin II receptor blocker pharmaceuticals. The switching strategy used in the proposed methodology eliminates organic interference and avoids the incompatibility issue with ARB ingredients. Under the optimal conditions, the proposed method exhibited satisfactory linearity in the range of 2.0-200.0 ng/mL, with a correlation coefficient of 0.9996. Validation studies demonstrated a detection limit (LOD, S/N = 3) of 0.57 ng/mL and a quantification limit (LOQ, S/N = 10) of 1.89 ng/mL, surpassing the sensitivity requirements in pharmacopeias. Method robustness was confirmed, with recovery rates from 92.8 to 108.7% using spiked ARBs real samples, and the intra-day and inter-day RSDs were less than 9.7%. The proposed approach establishes a reliable, precise, and sensitive alternative for monitoring azide impurities in ARBs, and such a framework can overcome limitations such as solubility issues, contributing to a universal applicability to diverse hydrophobic drugs.

Authors

Institutions

Publication Details

Journal
International Journal of Molecular Sciences
Published
2025-05-20
DOI
https://doi.org/10.3390/ijms26104895
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Automated and Precise Approach for the Determination of Azide Residue in Angiotensin II Receptor Blockers Using In Situ Matrix Elimination Ion Chromatography with Switching Strategy

Kaidi Zhang, Xiaolin Yu, Kai Zhang, Yan Zhu et al.
International Journal of Molecular Sciences
Analytical Methods in Pharmaceuticals
article

An Automated and Precise Approach for the Determination of Azide Residue in Angiotensin II Receptor Blockers Using In Situ Matrix Elimination Ion Chromatography with Switching Strategy

Kaidi Zhang, Xiaolin Yu, Kai Zhang, Yan Zhu, Shengyuan Pan, Chaoyan Lou
article en

Abstract

Angiotensin II receptor blockers (ARBs), a critical class of second-generation antihypertensive drugs, require azide intermediates for constructing their biphenyl tetrazole pharmacophore. This synthetic reaction introduces hypertoxicity risks, as residual azides can induce fatal damage even at trace concentrations. The pharmacopoeias of most countries have highlighted the urgency for improved detection paradigms of the control of azides in ARBs. Current ion chromatography (IC) methods face analytical challenges due to matrix interference from organic solvents and incompatibility with hydrophobic ARB ingredients. Herein, an in situ matrix elimination ion chromatography methodology was established for the sensitive detection of trace azides in angiotensin II receptor blocker pharmaceuticals. The switching strategy used in the proposed methodology eliminates organic interference and avoids the incompatibility issue with ARB ingredients. Under the optimal conditions, the proposed method exhibited satisfactory linearity in the range of 2.0-200.0 ng/mL, with a correlation coefficient of 0.9996. Validation studies demonstrated a detection limit (LOD, S/N = 3) of 0.57 ng/mL and a quantification limit (LOQ, S/N = 10) of 1.89 ng/mL, surpassing the sensitivity requirements in pharmacopeias. Method robustness was confirmed, with recovery rates from 92.8 to 108.7% using spiked ARBs real samples, and the intra-day and inter-day RSDs were less than 9.7%. The proposed approach establishes a reliable, precise, and sensitive alternative for monitoring azide impurities in ARBs, and such a framework can overcome limitations such as solubility issues, contributing to a universal applicability to diverse hydrophobic drugs.

International Journal of Molecular SciencesVol. 26(10)
Ningbo University (CN), China Jiliang University (CN), Zhejiang University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 88%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.