Inner Thermal Structure Evolution of Fire-Resistant Medium-Voltage Cable Under External Heat Flux with Varying Conductor Radius

Ensuring the fire resistance and thermal stability of power cables is crucial for their reliable performance in fire environments, essential for sustainable power distribution, and allowing for more time to extinguish fires and for evacuation. This study utilises numerical simulation to analyse the thermal behaviour of fire-resistant medium-voltage cable, focusing on the impact of conductor radius and material properties under external heat flux. A heat transfer model of cables with conductor radii of 3 mm, 5 mm, and 7 mm under a localised external heat flux of 750 °C was developed. The results show that smaller conductors stabilise faster (reaching the steady state at 45 min for 3 mm vs. 79 min for 7 mm) but experience higher thermal stress, with conductor temperatures peaking at 692.5 °C. Larger conductors enhance axial heat conduction, reduce steady-state temperature by up to 25%, and improve heat dissipation by over 360%. The 5 mm conductor radius provided balanced performance, lowering the temperature by 65 °C compared to 3 mm, although it remained 20.1% hotter than the 7 mm. The ceramic layer played a crucial role in reducing heat flux in the heat source section. Optimised polyethylene insulation and ceramic material improved heat retention and surface temperature control in non-heat source sections. Also, thermal resistance analysis decreased from 1.00 K/W (3 mm) to 0.65 K/W (7 mm). Among material properties, increasing ceramic thermal conductivity had a more significant impact on reducing core temperature than improving insulation. These findings provide practical recommendations for optimising conductor geometry and material properties for more fire-resistant cables.

Authors

Institutions

Publication Details

Journal
Fire
Published
2025-05-20
DOI
https://doi.org/10.3390/fire8050204
Citations
1
Primary Topic
Thermal Analysis in Power Transmission
Type
article
Field-Weighted Citation Impact
1.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Inner Thermal Structure Evolution of Fire-Resistant Medium-Voltage Cable Under External Heat Flux with Varying Conductor Radius

Mohmmed Mun ELseed Hassaan, Moayad S. M. Sedahmed
1 citations
Fire
Thermal Analysis in Power Transmission
1.21
article

Inner Thermal Structure Evolution of Fire-Resistant Medium-Voltage Cable Under External Heat Flux with Varying Conductor Radius

Mohmmed Mun ELseed Hassaan, Moayad S. M. Sedahmed
article en
1 citations

Abstract

Ensuring the fire resistance and thermal stability of power cables is crucial for their reliable performance in fire environments, essential for sustainable power distribution, and allowing for more time to extinguish fires and for evacuation. This study utilises numerical simulation to analyse the thermal behaviour of fire-resistant medium-voltage cable, focusing on the impact of conductor radius and material properties under external heat flux. A heat transfer model of cables with conductor radii of 3 mm, 5 mm, and 7 mm under a localised external heat flux of 750 °C was developed. The results show that smaller conductors stabilise faster (reaching the steady state at 45 min for 3 mm vs. 79 min for 7 mm) but experience higher thermal stress, with conductor temperatures peaking at 692.5 °C. Larger conductors enhance axial heat conduction, reduce steady-state temperature by up to 25%, and improve heat dissipation by over 360%. The 5 mm conductor radius provided balanced performance, lowering the temperature by 65 °C compared to 3 mm, although it remained 20.1% hotter than the 7 mm. The ceramic layer played a crucial role in reducing heat flux in the heat source section. Optimised polyethylene insulation and ceramic material improved heat retention and surface temperature control in non-heat source sections. Also, thermal resistance analysis decreased from 1.00 K/W (3 mm) to 0.65 K/W (7 mm). Among material properties, increasing ceramic thermal conductivity had a more significant impact on reducing core temperature than improving insulation. These findings provide practical recommendations for optimising conductor geometry and material properties for more fire-resistant cables.

FireVol. 8(5)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Institute of Plasma Physics (CN)
China Scholarship Council
Openalex Percentile: Top 21%
Thermal Analysis in Power Transmission
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.