Reduction of Fire Hazard in Individual Residential Buildings under the Conditions of Unbalanced and Nonlinear Loads

The article considers the possibilities of using methods and technical means to reduce the risk of fire-hazardous situations to occur in individual residential buildings (IRB) as a consequence of unbalanced operation modes caused by unbalanced and nonlinear loads. The maximum allowable current values through the neutral conductor of the IRB internal electrical network and in a 0.4 kV four-wire network under various temperature conditions have been determined. Based on the actual measurements of electrical energy parameters in the IRB internal electrical network, the connection of the newly developed balancing device to the IRB input distribution board was simulated. The effectiveness of using the balancing device was analyzed from the viewpoint of reducing the risk of fire to break out. It has been established that the use of a balancing device reduces heat losses, which can cause a fire hazard in the electrical network under study, by more than 60 %. The results obtained may be of interest to companies involved in the design and construction of IRBs, as well as to scientists who investigate unbalanced operating modes of low-voltage electric networks.

Authors

Publication Details

Journal
Elektrichestvo
Published
2025-05-20
DOI
https://doi.org/10.24160/0013-5380-2025-4-53-63
Primary Topic
Environmental and Industrial Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reduction of Fire Hazard in Individual Residential Buildings under the Conditions of Unbalanced and Nonlinear Loads

И. В. Наумов, I. V. Yamshchikovа, Sergey POD”YACHIH
Elektrichestvo
Environmental and Industrial Safety
article

Reduction of Fire Hazard in Individual Residential Buildings under the Conditions of Unbalanced and Nonlinear Loads

И. В. Наумов, I. V. Yamshchikovа, Sergey POD”YACHIH
article en

Abstract

The article considers the possibilities of using methods and technical means to reduce the risk of fire-hazardous situations to occur in individual residential buildings (IRB) as a consequence of unbalanced operation modes caused by unbalanced and nonlinear loads. The maximum allowable current values through the neutral conductor of the IRB internal electrical network and in a 0.4 kV four-wire network under various temperature conditions have been determined. Based on the actual measurements of electrical energy parameters in the IRB internal electrical network, the connection of the newly developed balancing device to the IRB input distribution board was simulated. The effectiveness of using the balancing device was analyzed from the viewpoint of reducing the risk of fire to break out. It has been established that the use of a balancing device reduces heat losses, which can cause a fire hazard in the electrical network under study, by more than 60 %. The results obtained may be of interest to companies involved in the design and construction of IRBs, as well as to scientists who investigate unbalanced operating modes of low-voltage electric networks.

Elektrichestvo(4)
Sustainable cities and communities
Openalex Percentile: Top 91%
Environmental and Industrial Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.