Improving the Electric Load Calculation for Apartment Buildings Based on Their Specific Power Capacity

The revision of regulatory documents aimed at improving the design of urban power supply systems makes it relevant to scrutinize the currently used methods for calculating the electrical loads that determine the number and capacity of transformer substations, cross-sections of power supply cables, and the estimated capacity of the utility connection. The methodology used in designing a residential microdistrict power supply system is focused on how the total living space of apartment buildings is used. Its advantage lies in the simplicity of calculations, but the lack of adaptation to a decrease in the actual specific load per unit area with its growth plus an overestimated fixed standard value give an unreliable final result. To preserve the advantages of the method, it is proposed to adjust it toward bringing the results of calculating the total power consumed by apartment buildings from substation buses closer to the actual load values. The daily load schedules of apartment buildings of standard designs equipped with electric stoves in the range of 11–25 floors were monitored. Measurements were taken at input switchgears. The electricity consumption of apartments, electrical receivers of common house needs, and a relatively small commercial load of apartment buildings were recorded at half-hour intervals. Statistical processing of measurements has shown that apartment buildings of 11–18 floors and 19–25 floors can be united into a common cluster based on the maximum specific load. By combining the daily load schedules for different numbers of apartment buildings, the dependence of specific load values on the building total area has been constructed. It has been shown that the results of calculating the apartment building total load correspond to the results of its calculation based on the specific load (of apartments), taking into account the common house needs and commercial load.

Authors

Publication Details

Journal
Elektrichestvo
Published
2025-05-20
DOI
https://doi.org/10.24160/0013-5380-2025-5-28-38
Citations
1
Primary Topic
Advanced Algorithms and Applications
Type
article
Field-Weighted Citation Impact
1.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving the Electric Load Calculation for Apartment Buildings Based on Their Specific Power Capacity

Azat AHMETSHIN, A. I. Fedotov, Evgeniy Fedotov, Viktor Kulakov et al.
1 citations
Elektrichestvo
Advanced Algorithms and Applications
1.21
article

Improving the Electric Load Calculation for Apartment Buildings Based on Their Specific Power Capacity

Azat AHMETSHIN, A. I. Fedotov, Evgeniy Fedotov, Viktor Kulakov, N Chernova
article en
1 citations

Abstract

The revision of regulatory documents aimed at improving the design of urban power supply systems makes it relevant to scrutinize the currently used methods for calculating the electrical loads that determine the number and capacity of transformer substations, cross-sections of power supply cables, and the estimated capacity of the utility connection. The methodology used in designing a residential microdistrict power supply system is focused on how the total living space of apartment buildings is used. Its advantage lies in the simplicity of calculations, but the lack of adaptation to a decrease in the actual specific load per unit area with its growth plus an overestimated fixed standard value give an unreliable final result. To preserve the advantages of the method, it is proposed to adjust it toward bringing the results of calculating the total power consumed by apartment buildings from substation buses closer to the actual load values. The daily load schedules of apartment buildings of standard designs equipped with electric stoves in the range of 11–25 floors were monitored. Measurements were taken at input switchgears. The electricity consumption of apartments, electrical receivers of common house needs, and a relatively small commercial load of apartment buildings were recorded at half-hour intervals. Statistical processing of measurements has shown that apartment buildings of 11–18 floors and 19–25 floors can be united into a common cluster based on the maximum specific load. By combining the daily load schedules for different numbers of apartment buildings, the dependence of specific load values on the building total area has been constructed. It has been shown that the results of calculating the apartment building total load correspond to the results of its calculation based on the specific load (of apartments), taking into account the common house needs and commercial load.

Elektrichestvo(5)
Affordable and clean energy
Openalex Percentile: Top 21%
Advanced Algorithms and Applications
1.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving the Electric Load Calculation for Apartment Buildings Based on Their Specific Power Capacity — Azat AHMETSHIN, A. I. Fedotov, et al. · Elektrichestvo (2025) | TGRS Research Map | TGRS