Experimental Study on Multi-Cell Counting Using an Inertial Microfluidic Device

Inertial microfluidics has gained significant attention for cell counting applications due to its simplicity, high throughput, and precision. This study utilized an inertial flow microfluidic device to count blood cell-sized microparticles, simulating normal and diseased conditions. The device could focus on and count cells sized between 7 µm and 16 µm while being observed under optical microscopes, with controlled flow rates from 1 to 15 µL/min. Suspensions of cells with ratios of 600:1 for normal conditions and 400:1 for diseased conditions were studied in microchannels at different flow rates. The methodology for counting involved using a syringe pump for precise flow actuation and employing an image-based particle counting technique through optical microscopy, utilizing the passive technique of inertial microfluidics. Results were compared using two optical microscopes across both suspension types. The key findings showed that at a 600:1 ratio of 8 µm and 15 µm cells, counts of 6.45 × 107 cells/mL and 1.10 × 107 cells/mL, respectively, while in the 400:1 ratio of both cells, counts of 4.5 × 107 cells/mL and 2.16 × 107 cells/mL, respectively, were achieved at optimal parameters. This study employed an inertial flow microfluidic device to count microparticles the size of blood cells. We assessed the counting performance using optical microscopy at two different cell ratios and validated our results against hemocytometer counts. Our findings demonstrate that the channel size 150 µm and the flow rate at 1 µL/min provided the optimal counting accuracy for both particle sizes. This device offers an efficient and adaptable solution for accurate multi-cell counting under optimized conditions and supporting applications in resource-limited medical diagnostics.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-05-20
DOI
https://doi.org/10.3390/app15105701
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental Study on Multi-Cell Counting Using an Inertial Microfluidic Device

Emad Uddin, Muhammad Zulfiqar, Aamir Mubashar, Sibghat Ullah et al.
3 links
Applied Sciences
Innovative Microfluidic and Catalytic Techniques Innovation
article

Experimental Study on Multi-Cell Counting Using an Inertial Microfluidic Device

Emad Uddin, Muhammad Zulfiqar, Aamir Mubashar, Sibghat Ullah, Zaib Ali, Danish Manshad, Muhammad Irfan, Jingmin Li
article en

Abstract

Inertial microfluidics has gained significant attention for cell counting applications due to its simplicity, high throughput, and precision. This study utilized an inertial flow microfluidic device to count blood cell-sized microparticles, simulating normal and diseased conditions. The device could focus on and count cells sized between 7 µm and 16 µm while being observed under optical microscopes, with controlled flow rates from 1 to 15 µL/min. Suspensions of cells with ratios of 600:1 for normal conditions and 400:1 for diseased conditions were studied in microchannels at different flow rates. The methodology for counting involved using a syringe pump for precise flow actuation and employing an image-based particle counting technique through optical microscopy, utilizing the passive technique of inertial microfluidics. Results were compared using two optical microscopes across both suspension types. The key findings showed that at a 600:1 ratio of 8 µm and 15 µm cells, counts of 6.45 × 107 cells/mL and 1.10 × 107 cells/mL, respectively, while in the 400:1 ratio of both cells, counts of 4.5 × 107 cells/mL and 2.16 × 107 cells/mL, respectively, were achieved at optimal parameters. This study employed an inertial flow microfluidic device to count microparticles the size of blood cells. We assessed the counting performance using optical microscopy at two different cell ratios and validated our results against hemocytometer counts. Our findings demonstrate that the channel size 150 µm and the flow rate at 1 µL/min provided the optimal counting accuracy for both particle sizes. This device offers an efficient and adaptable solution for accurate multi-cell counting under optimized conditions and supporting applications in resource-limited medical diagnostics.

Applied SciencesVol. 15(10)
Dalian University of Technology (CN), Capital University of Science and Technology (PK), University of Management and Technology (PK), National University of Sciences and Technology (PK)
Openalex Percentile: Top 90%
Innovative Microfluidic and Catalytic Techniques Innovation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.