Development of an electrochemical sensor based on Ni-Bio-MOF and a molecular imprinted polymer for determination of diclofenac: electrochemical and DFT investigations

In this work, a metal-organic nickel framework (Ni-MOF) modified with a biological ligand (asparagine) (Ni-Bio-MOF) was synthesized by a hydrothermal method. Asparagine is believed to create defects on the surface of the MOF, thereby increasing its electrocatalytic activity. Then, a Diclofenac (DCF) polymer imprinted with l-methionine (PL-Met) was electrodeposited on a carbon paste electrode (CPE)/Ni-Bio-MOF and used as a new electrochemical sensor for highly selective and sensitive detection of DCF in biological and pharmaceutical samples. The Ni-Bio-MOF/MIP-PL-Met nanocomposite was characterized using the following techniques: FT-IR, FE-SEM, TEM, HR-TEM, XRD, XPS, and EDX. The electrochemical properties and performance of the sensor for the electrooxidation of DCF were assessed using CV, DPV, and EIS techniques. The electrochemical behavior of CPE/Ni-Bio-MOF/MIP-PL-Met and non-imprinted polymer (NIP) with an imprinting factor of 6.64 was investigated, and the influencing parameters in DCF measurement were optimized by cyclic voltammetry (CV). This modified sensor showed three dynamic ranges at 1.0-500.0 pM, 1.0-1000.0 nM, and 1.0-1000.0 μM of DCF with a limited detection (LOD) of 0.17 pM, sensitivity of 2015.5 μA μM<sup>-1</sup> cm<sup>-2</sup>, relative standard deviation (RSD) of 3.3%, and reproducibility of 96.2%. Real samples of healthy human blood serum and DCF tablets were used to evaluate the practical application of the CPE/Ni-Bio-MOF/MIP-PL-Met electrochemical sensor. This method is simple, low-cost, with good limited detection, high sensitivity, and selectivity. The interactions of PL-Met with DCF were studied at the B3LYP/6-311++G(d,p) level of theory in both gaseous and aqueous phases. Additionally, the computational methodology investigated the thermodynamic stability of the proposed configurations and the role of hydrogen bonds in this system.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ra00194c
Citations
11
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
8.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of an electrochemical sensor based on Ni-Bio-MOF and a molecular imprinted polymer for determination of diclofenac: electrochemical and DFT investigations

Kh. Ghanbari, Mansoureh Zahedi-Tabrizi, Samaneh Ebadi
11 citations
RSC Advances
Analytical chemistry methods development
8.28
article

Development of an electrochemical sensor based on Ni-Bio-MOF and a molecular imprinted polymer for determination of diclofenac: electrochemical and DFT investigations

Kh. Ghanbari, Mansoureh Zahedi-Tabrizi, Samaneh Ebadi
article en
11 citations

Abstract

In this work, a metal-organic nickel framework (Ni-MOF) modified with a biological ligand (asparagine) (Ni-Bio-MOF) was synthesized by a hydrothermal method. Asparagine is believed to create defects on the surface of the MOF, thereby increasing its electrocatalytic activity. Then, a Diclofenac (DCF) polymer imprinted with l-methionine (PL-Met) was electrodeposited on a carbon paste electrode (CPE)/Ni-Bio-MOF and used as a new electrochemical sensor for highly selective and sensitive detection of DCF in biological and pharmaceutical samples. The Ni-Bio-MOF/MIP-PL-Met nanocomposite was characterized using the following techniques: FT-IR, FE-SEM, TEM, HR-TEM, XRD, XPS, and EDX. The electrochemical properties and performance of the sensor for the electrooxidation of DCF were assessed using CV, DPV, and EIS techniques. The electrochemical behavior of CPE/Ni-Bio-MOF/MIP-PL-Met and non-imprinted polymer (NIP) with an imprinting factor of 6.64 was investigated, and the influencing parameters in DCF measurement were optimized by cyclic voltammetry (CV). This modified sensor showed three dynamic ranges at 1.0-500.0 pM, 1.0-1000.0 nM, and 1.0-1000.0 μM of DCF with a limited detection (LOD) of 0.17 pM, sensitivity of 2015.5 μA μM<sup>-1</sup> cm<sup>-2</sup>, relative standard deviation (RSD) of 3.3%, and reproducibility of 96.2%. Real samples of healthy human blood serum and DCF tablets were used to evaluate the practical application of the CPE/Ni-Bio-MOF/MIP-PL-Met electrochemical sensor. This method is simple, low-cost, with good limited detection, high sensitivity, and selectivity. The interactions of PL-Met with DCF were studied at the B3LYP/6-311++G(d,p) level of theory in both gaseous and aqueous phases. Additionally, the computational methodology investigated the thermodynamic stability of the proposed configurations and the role of hydrogen bonds in this system.

RSC AdvancesVol. 15(21)
Alzahra University (IR)
Alzahra University
Openalex Percentile: Top 2%
Analytical chemistry methods development
8.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.