Comparative Analysis of Pulsed and Continuous Wave Modes in High‐Intensity Laser Light Therapy: Implications for Deep Tissue Treatment

High-intensity laser at a wavelength of 1064 nm has gained significant attention in the field of therapeutic applications due to its potential to penetrate deeper. Continuous wave laser therapy, although effective, poses a challenge of elevated skin temperature. This study endeavors to explore the transition from continuous to pulsed laser, aiming to enhance light fluence in deep tissue while mitigating skin temperature rise. Investigating continuous versus pulsed wave in transdermal deep tissue light therapy, this research utilizes a high-intensity laser at 1064 nm to optimize fluence in deep muscle tissue of the human knee, minimizing absorption-driven skin temperature rise. Simulated parameters, including peak power (60 W), pulse width (2 ms), duty cycle (10%), frequency (50 Hz), as well as beam size of 20 mm, indicate that pulsed wave irradiation after 300 s achieved the lowest skin surface temperature (42.5°C) and the highest fluence (approximately 4.2 J/cm<sup>2</sup>).

Authors

Institutions

Publication Details

Journal
Journal of Biophotonics
Published
2025-05-19
DOI
https://doi.org/10.1002/jbio.202400164
Citations
4
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
5.44

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Pulsed and Continuous Wave Modes in High‐Intensity Laser Light Therapy: Implications for Deep Tissue Treatment

Chironjeet Chaki, Kwong Ming Tse, Luis De Taboada
4 citations
Journal of Biophotonics
Laser Applications in Dentistry and Medicine
5.44
article

Comparative Analysis of Pulsed and Continuous Wave Modes in High‐Intensity Laser Light Therapy: Implications for Deep Tissue Treatment

Chironjeet Chaki, Kwong Ming Tse, Luis De Taboada
article en
4 citations

Abstract

High-intensity laser at a wavelength of 1064 nm has gained significant attention in the field of therapeutic applications due to its potential to penetrate deeper. Continuous wave laser therapy, although effective, poses a challenge of elevated skin temperature. This study endeavors to explore the transition from continuous to pulsed laser, aiming to enhance light fluence in deep tissue while mitigating skin temperature rise. Investigating continuous versus pulsed wave in transdermal deep tissue light therapy, this research utilizes a high-intensity laser at 1064 nm to optimize fluence in deep muscle tissue of the human knee, minimizing absorption-driven skin temperature rise. Simulated parameters, including peak power (60 W), pulse width (2 ms), duty cycle (10%), frequency (50 Hz), as well as beam size of 20 mm, indicate that pulsed wave irradiation after 300 s achieved the lowest skin surface temperature (42.5°C) and the highest fluence (approximately 4.2 J/cm<sup>2</sup>).

Journal of BiophotonicsVol. 18(7)
Swinburne University of Technology (AU)
Swinburne University of Technology
Good health and well-being
Openalex Percentile: Top 4%
Laser Applications in Dentistry and Medicine
5.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.