Clinical Validation and Post-Implementation Performance Monitoring of a Neural Network-Assisted Approach for Detecting Chronic Lymphocytic Leukemia Minimal Residual Disease by Flow Cytometry
<b>Background</b>: Flow cytometric detection of minimal residual disease (MRD) in chronic lymphocytic leukemia (CLL) is complex, time-consuming, and subject to inter-operator variability. Deep neural networks (DNNs) offer potential for standardization and efficiency improvement, but require rigorous validation and monitoring for safe clinical implementation. <b>Methods</b>: We evaluated a DNN-assisted human-in-the-loop approach for CLL MRD detection. Initial validation included method comparison against manual analysis (n = 240), precision studies, and analytical sensitivity verification. Post-implementation monitoring comprised four components: daily electronic quality control, input data drift detection, error analysis, and attribute acceptance sampling. Laboratory efficiency was assessed through a timing study of 161 cases analyzed by five technologists. <b>Results</b>: Method comparison demonstrated 97.5% concordance with manual analysis for qualitative classification (sensitivity 100%, specificity 95%) and excellent correlation for quantitative assessment (r = 0.99, Deming slope = 0.99). Precision studies confirmed high repeatability and within-laboratory precision across multiple operators. Analytical sensitivity was verified at 0.002% MRD. Post-implementation monitoring identified 2.97% of cases (26/874) with input data drift, primarily high-burden CLL and non-CLL neoplasms. Error analysis showed the DNN alone achieved 97% sensitivity compared to human-in-the-loop-reviewed results, with 13 missed cases (1.5%) showing atypical immunophenotypes. Attribute acceptance sampling confirmed 98.8% of reported negative cases were true negatives. The DNN-assisted workflow reduced average analysis time by 60.3% compared to manual analysis (4.2 ± 2.3 vs. 10.5 ± 5.8 min). <b>Conclusions</b>: The implementation of a DNN-assisted approach for CLL MRD detection in a clinical laboratory provides diagnostic performance equivalent to expert manual analysis while substantially reducing analysis time. Comprehensive performance monitoring ensures ongoing safety and effectiveness in routine clinical practice. This approach provides a model for responsible AI integration in clinical laboratories, balancing automation benefits with expert oversight.
Authors
- Jansen N. Seheult (ORCID: https://orcid.org/0000-0002-6850-7495)
- Dragan Jevremović (ORCID: https://orcid.org/0000-0002-1792-5822)
- Horatiu Olteanu (ORCID: https://orcid.org/0000-0001-5783-4485)
- Min Shi (ORCID: https://orcid.org/0000-0002-5741-4293)
- Wenchao Han
- Gregory E. Otteson
- Pedro Horna (ORCID: https://orcid.org/0000-0003-4909-6157)
- Matthew J. Weybright
- Michael Timm
Institutions
- Mayo Clinic (US)
Publication Details
- Journal
- Cancers
- Published
- 2025-05-17
- DOI
- https://doi.org/10.3390/cancers17101688
- Citations
- 5
- Primary Topic
- Chronic Lymphocytic Leukemia Research
- Type
- article
- Field-Weighted Citation Impact
- 8.13