Comparative dosimetric evaluation of hybrid volumetric modulated arc therapy techniques for oesophageal cancer: a treatment planning study

Abstract Objective: To find the optimal dose weighting for a combination of three-dimensional conformal radiotherapy (3DCRT) and hybrid volumetric modulated arc therapy (hVMAT) plans for thoracic oesophageal cancer radiation therapy. Methods and Materials: This retrospective study involved fourteen patients diagnosed with carcinoma of the oesophagus previously treated with VMAT radiotherapy techniques. Four hVMAT plans were developed for each patient, with a prescribed dose of 50.4 Gy delivered over 28 fractions. The plans incorporated varying ratios of 3DCRT and VMAT techniques: hVMAT-1(33% 2F 3DCRT/67% VMAT), hVMAT-2 (33% 3F 3DCRT/67% VMAT), hVMAT-3 (67% 2F 3DCRT/33% VMAT), and hVMAT-4 (67% 3F 3DCRT/33% VMAT). Dose volume histograms were used to assess the coverage of the planning target volume (PTV) and to analyse dosimetric parameters, including the doses received by organs at risk. Result: In the four hVMAT techniques, statistically insignificant differences were observed in PTV doses, conformity index and homogeneity index. Notably, monitor unit values differed significantly in three techniques, except for hVMAT-1(p = 0.358). hVMAT-3 demonstrated lower lung mean dose and lung V 20Gy values (14.5±3.97, 21.09 ± 9.02) compared to other techniques. There were statistically significant differences in heart mean doses between hVMAT-1 and hVMAT-2, or hVMAT-3 and hVMAT-4 plans (p = 0.462, p = 0.542). However, a significant difference in spinal cord Dmax was found only in hVMAT-1(p = 0.024). Conclusion: The hVMAT -1 and hVMAT-2 techniques (33% 2F 3DCRT/67% Arc) appear to be the most suitable weighting for the hybrid VMAT technique, offering optimal sparing of the lungs and heart while ensuring adequate coverage of the planning target volume.

Authors

Institutions

Publication Details

Journal
Journal of Radiotherapy in Practice
Published
2025-01-01
DOI
https://doi.org/10.1017/s1460396925000160
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative dosimetric evaluation of hybrid volumetric modulated arc therapy techniques for oesophageal cancer: a treatment planning study

Dinesh Kumar Sinha, Mukesh Kumar Zope, Devraj Singh, Seema Devi et al.
Journal of Radiotherapy in Practice
Advanced Radiotherapy Techniques
article

Comparative dosimetric evaluation of hybrid volumetric modulated arc therapy techniques for oesophageal cancer: a treatment planning study

Dinesh Kumar Sinha, Mukesh Kumar Zope, Devraj Singh, Seema Devi, Deepali Patil, Dinesh Kumar Saroj
article en

Abstract

Abstract Objective: To find the optimal dose weighting for a combination of three-dimensional conformal radiotherapy (3DCRT) and hybrid volumetric modulated arc therapy (hVMAT) plans for thoracic oesophageal cancer radiation therapy. Methods and Materials: This retrospective study involved fourteen patients diagnosed with carcinoma of the oesophagus previously treated with VMAT radiotherapy techniques. Four hVMAT plans were developed for each patient, with a prescribed dose of 50.4 Gy delivered over 28 fractions. The plans incorporated varying ratios of 3DCRT and VMAT techniques: hVMAT-1(33% 2F 3DCRT/67% VMAT), hVMAT-2 (33% 3F 3DCRT/67% VMAT), hVMAT-3 (67% 2F 3DCRT/33% VMAT), and hVMAT-4 (67% 3F 3DCRT/33% VMAT). Dose volume histograms were used to assess the coverage of the planning target volume (PTV) and to analyse dosimetric parameters, including the doses received by organs at risk. Result: In the four hVMAT techniques, statistically insignificant differences were observed in PTV doses, conformity index and homogeneity index. Notably, monitor unit values differed significantly in three techniques, except for hVMAT-1(p = 0.358). hVMAT-3 demonstrated lower lung mean dose and lung V 20Gy values (14.5±3.97, 21.09 ± 9.02) compared to other techniques. There were statistically significant differences in heart mean doses between hVMAT-1 and hVMAT-2, or hVMAT-3 and hVMAT-4 plans (p = 0.462, p = 0.542). However, a significant difference in spinal cord Dmax was found only in hVMAT-1(p = 0.024). Conclusion: The hVMAT -1 and hVMAT-2 techniques (33% 2F 3DCRT/67% Arc) appear to be the most suitable weighting for the hybrid VMAT technique, offering optimal sparing of the lungs and heart while ensuring adequate coverage of the planning target volume.

Journal of Radiotherapy in PracticeVol. 24
Indira Gandhi Institute of Medical Sciences (IN), Medical Research Foundation (GB), Veer Bahadur Singh Purvanchal University (IN)
Openalex Percentile: Top 87%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.