Electro‐Sensing Analysis for Parkinson's Disease Biomarker on Dual‐Electrode Surface: Complemented by Molecular Docking

This study was designed to improve the sensitivity, specificity, and selectivity of the electrochemical method of detecting Parkinson's disease by identifying alpha-synuclein as a biomarker using gold interdigitated electrodes (AuIDEs with and without surface modified with zinc oxide (ZnO). AuIDE modified with zinc oxide and AuIDE without zinc oxide were characterized using a scanning electron microscope, 3D profilometers, and a high-power microscope. Current-voltage measurements were performed for antigen-antibody interaction and targeted detection using a Keithley 6482 Picoammeter. The linear range was from 1 fM to 1 pM. The limit of detections for AuIDE modified with zinc oxide and AuIDE without zinc oxide were calculated using the signal-to-noise ratio (S/N) = 3 formula. Linear regression analysis of the AuIDE without zinc oxide was R<sup>2</sup> of 0.9779. The linear regression analysis for AuIDE with zinc oxide was R<sup>2</sup> = 0.9809. Regression analysis thus yielded a better result in the modified AuIDE. For the determination of selectivity, alpha-synuclein and tau were tested on the surface-modified AuIDE. Tau was used as a control variable. However, only alpha-synuclein produced significant current change, while the control protein yielded no significant changes. Hence, the inclusion of the ZnO layer improved the sensor's performance and the sensor was reproducible and stable after repeated testing.

Authors

Institutions

Publication Details

Journal
Biotechnology and Applied Biochemistry
Published
2025-05-19
DOI
https://doi.org/10.1002/bab.2775
Citations
1
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electro‐Sensing Analysis for Parkinson's Disease Biomarker on Dual‐Electrode Surface: Complemented by Molecular Docking

Muhammad Mahyiddin Ramli, Evan Tareq Salim, Tijjani Adam, Makram A. Fakhri et al.
1 citations
Biotechnology and Applied Biochemistry
Conducting polymers and applications
0.61
article

Electro‐Sensing Analysis for Parkinson's Disease Biomarker on Dual‐Electrode Surface: Complemented by Molecular Docking

Muhammad Mahyiddin Ramli, Evan Tareq Salim, Tijjani Adam, Makram A. Fakhri, M. N. A. Uda, Hussaini Adam, M. K. Md Arshad, Chun Hong Voon, T. Ashokkumar, Thirumananseri Kumarevel
article en
1 citations

Abstract

This study was designed to improve the sensitivity, specificity, and selectivity of the electrochemical method of detecting Parkinson's disease by identifying alpha-synuclein as a biomarker using gold interdigitated electrodes (AuIDEs with and without surface modified with zinc oxide (ZnO). AuIDE modified with zinc oxide and AuIDE without zinc oxide were characterized using a scanning electron microscope, 3D profilometers, and a high-power microscope. Current-voltage measurements were performed for antigen-antibody interaction and targeted detection using a Keithley 6482 Picoammeter. The linear range was from 1 fM to 1 pM. The limit of detections for AuIDE modified with zinc oxide and AuIDE without zinc oxide were calculated using the signal-to-noise ratio (S/N) = 3 formula. Linear regression analysis of the AuIDE without zinc oxide was R<sup>2</sup> of 0.9779. The linear regression analysis for AuIDE with zinc oxide was R<sup>2</sup> = 0.9809. Regression analysis thus yielded a better result in the modified AuIDE. For the determination of selectivity, alpha-synuclein and tau were tested on the surface-modified AuIDE. Tau was used as a control variable. However, only alpha-synuclein produced significant current change, while the control protein yielded no significant changes. Hence, the inclusion of the ZnO layer improved the sensor's performance and the sensor was reproducible and stable after repeated testing.

Biotechnology and Applied BiochemistryVol. 72(6)
Haramaya University (ET), University of Technology - Iraq (IQ), Western Caspian University (AZ), RIKEN Center for Integrative Medical Sciences (JP), Universiti Malaysia Perlis (MY), Saveetha University (IN)
Openalex Percentile: Top 36%
Conducting polymers and applications
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.