Biostrap Kairos Wristband Versus Electrocardiography for Resting Heart Rate Variability Assessment

The Kairos wristband offers on-demand heart rate variability (HRV) assessment through its "Spot Check" feature, enabling standardized recordings for clinical, research, or self-tracking purposes, but its validity is untested. Therefore, we compared the Kairos wristband to electrocardiography (ECG) for resting HRV assessment in young adults, and investigated the influence of skin pigmentation (M-index) on measurement accuracy. Simultaneous 3 min Kairos and ECG samples were obtained in the supine (n = 32) and seated (n = 30) position. Comparisons included resting heart rate (RHR) and time domain (root-mean square of successive differences [RMSSD], standard deviation of normal RR intervals [SDNN]), frequency domain (low [LF] and high frequency [HF]), and non-linear (standard deviation 1 [SD1] and SD2) HRV metrics. RHR showed excellent agreement whereas HF, LF, and SD2 showed poor agreement. For the remaining metrics, SDNN showed the strongest absolute and relative agreement, followed by SD1 and RMSSD. However, most HRV metrics exhibited heteroscedasticity or proportional bias, with greater error and underestimation at higher HRV values. M-index was unrelated to method difference scores, except for seated SD2 (<i>p</i> = 0.01). The Kairos wristband can be used to measure RHR, but HRV assessment should be limited to SDNN for global variability and SD1 or RMSSD for cardiac-parasympathetic activity. However, these metrics should be interpreted within the level of agreement identified in this study, and with consideration of the observed trend of diminished accuracy with higher HRV values.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-05-17
DOI
https://doi.org/10.3390/s25103165
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biostrap Kairos Wristband Versus Electrocardiography for Resting Heart Rate Variability Assessment

Angie Wade, Andrew A. Flatt, Bryan L. Riemann, Ann Claire E. Blalock
Sensors
Heart Rate Variability and Autonomic Control
article

Biostrap Kairos Wristband Versus Electrocardiography for Resting Heart Rate Variability Assessment

Angie Wade, Andrew A. Flatt, Bryan L. Riemann, Ann Claire E. Blalock
article en

Abstract

The Kairos wristband offers on-demand heart rate variability (HRV) assessment through its "Spot Check" feature, enabling standardized recordings for clinical, research, or self-tracking purposes, but its validity is untested. Therefore, we compared the Kairos wristband to electrocardiography (ECG) for resting HRV assessment in young adults, and investigated the influence of skin pigmentation (M-index) on measurement accuracy. Simultaneous 3 min Kairos and ECG samples were obtained in the supine (n = 32) and seated (n = 30) position. Comparisons included resting heart rate (RHR) and time domain (root-mean square of successive differences [RMSSD], standard deviation of normal RR intervals [SDNN]), frequency domain (low [LF] and high frequency [HF]), and non-linear (standard deviation 1 [SD1] and SD2) HRV metrics. RHR showed excellent agreement whereas HF, LF, and SD2 showed poor agreement. For the remaining metrics, SDNN showed the strongest absolute and relative agreement, followed by SD1 and RMSSD. However, most HRV metrics exhibited heteroscedasticity or proportional bias, with greater error and underestimation at higher HRV values. M-index was unrelated to method difference scores, except for seated SD2 (<i>p</i> = 0.01). The Kairos wristband can be used to measure RHR, but HRV assessment should be limited to SDNN for global variability and SD1 or RMSSD for cardiac-parasympathetic activity. However, these metrics should be interpreted within the level of agreement identified in this study, and with consideration of the observed trend of diminished accuracy with higher HRV values.

SensorsVol. 25(10)
Georgia Southern University (US)
No poverty
Openalex Percentile: Top 80%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.