ИССЛЕДОВАНИЕ ОСНОВНЫХ ПРИЧИН ОТКАЗОВ И РАСЧЁТ СКОРОСТИ ОБТЕКАНИЯ ДВИГАТЕЛЯ ПОГРУЖНОГО НАСОСА

The article studies common causes of submersible pumps failure. The influence of formation temperature on the operation of submersible pumps is studied. Negative factors appearing, at increase of temperature of electric motor of submersible pump are studied. The influence of high temperature on the material of submersible pump has been studied. The effect and methods of installation of cooling casing for submersible pump are studied. Calculated the flow velocity passing near the electric motor part of the submersible pump. Determined the optimum diameter of the cooling jacket for the submersible pump.

Authors

Institutions

Publication Details

Journal
Sanoatda raqamli texnologiyalar.
Published
2025-05-19
DOI
https://doi.org/10.70769/3030-3214.srt.3.2.2025.21
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ИССЛЕДОВАНИЕ ОСНОВНЫХ ПРИЧИН ОТКАЗОВ И РАСЧЁТ СКОРОСТИ ОБТЕКАНИЯ ДВИГАТЕЛЯ ПОГРУЖНОГО НАСОСА

L. N. Atakulov, Ойбек Мухамматкулович Курбонов, Мафтуна Давроновна Сафарова
3 links
Sanoatda raqamli texnologiyalar.
Engineering Diagnostics and Reliability
article

ИССЛЕДОВАНИЕ ОСНОВНЫХ ПРИЧИН ОТКАЗОВ И РАСЧЁТ СКОРОСТИ ОБТЕКАНИЯ ДВИГАТЕЛЯ ПОГРУЖНОГО НАСОСА

L. N. Atakulov, Ойбек Мухамматкулович Курбонов, Мафтуна Давроновна Сафарова
article en

Abstract

The article studies common causes of submersible pumps failure. The influence of formation temperature on the operation of submersible pumps is studied. Negative factors appearing, at increase of temperature of electric motor of submersible pump are studied. The influence of high temperature on the material of submersible pump has been studied. The effect and methods of installation of cooling casing for submersible pump are studied. Calculated the flow velocity passing near the electric motor part of the submersible pump. Determined the optimum diameter of the cooling jacket for the submersible pump.

Sanoatda raqamli texnologiyalar.Vol. 3(2)
Dalton State College (US), Public Health Dayton & Montgomery County (US)
Openalex Percentile: Top 88%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.