Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up

<b>Background</b>: To compare the efficacy and safety of the XEN<sup>®</sup> 63 µm and 45 µm devices with the ab externo open conjunctiva with a 30G needle approach. <b>Methods</b>: A retrospective, non-randomized and single-center study was conducted. Consecutive eyes undergoing a XEN<sup>®</sup> 63 µm implant were compared with a matched cohort of cases with a XEN<sup>®</sup> 45 µm implant. Standalone and combined procedures with phacoemulsification were included. <b>Results</b>: A total of 28 XEN<sup>®</sup> 45 µm and 28 XEN<sup>®</sup> 63 µm were included. Complete surgical success was achieved in 17 cases (60.7%) in the 45 µm group and in 20 cases (71.4%) in the 63 µm group, with no statistical differences. One year after the surgery, the mean IOP was 13.8 ± 3.3 mmHg for the 45 µm group and 12.4 ± 4.2 mmHg for the 63 µm group (<i>p</i>-value > 0.05). Likewise, the use of glaucoma medication was lowered in the 63 µm device (0.32 ± 0.87) compared to the 45 µm device (0.39 ± 0.86), with no statistical significance. Postoperative hypotony was more frequent in the 63 µm device (39.3%) than in the 45 µm group (28.6%), with no statistical differences. However, hypotony-associated complications (including choroidal detachment, hypotony keratopathy, and hypotony maculopathy) were significantly higher in the 63 µm group (<i>p</i> = 0.011). <b>Conclusions:</b> Although the XEN<sup>®</sup> 63 µm may offer a greater IOP-lowering effect with better complete surgical success, no significant differences were detected compared to the 45 µm device. Hypotony-related complications were higher in the XEN 63 µm, although most of them resolved with conservative management.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-19
DOI
https://doi.org/10.3390/jcm14103545
Citations
1
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
1.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up

Manuel Amilburu, Antonio Dou, Laura Sánchez-Vela, Olivia Pujol-Carreras et al.
1 citations
Journal of Clinical Medicine
Glaucoma and retinal disorders
1.71
article

Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up

Manuel Amilburu, Antonio Dou, Laura Sánchez-Vela, Olivia Pujol-Carreras, Marta Castany, Yann Bertolani, Jaume Rigo-Quera
article en
1 citations

Abstract

<b>Background</b>: To compare the efficacy and safety of the XEN<sup>®</sup> 63 µm and 45 µm devices with the ab externo open conjunctiva with a 30G needle approach. <b>Methods</b>: A retrospective, non-randomized and single-center study was conducted. Consecutive eyes undergoing a XEN<sup>®</sup> 63 µm implant were compared with a matched cohort of cases with a XEN<sup>®</sup> 45 µm implant. Standalone and combined procedures with phacoemulsification were included. <b>Results</b>: A total of 28 XEN<sup>®</sup> 45 µm and 28 XEN<sup>®</sup> 63 µm were included. Complete surgical success was achieved in 17 cases (60.7%) in the 45 µm group and in 20 cases (71.4%) in the 63 µm group, with no statistical differences. One year after the surgery, the mean IOP was 13.8 ± 3.3 mmHg for the 45 µm group and 12.4 ± 4.2 mmHg for the 63 µm group (<i>p</i>-value > 0.05). Likewise, the use of glaucoma medication was lowered in the 63 µm device (0.32 ± 0.87) compared to the 45 µm device (0.39 ± 0.86), with no statistical significance. Postoperative hypotony was more frequent in the 63 µm device (39.3%) than in the 45 µm group (28.6%), with no statistical differences. However, hypotony-associated complications (including choroidal detachment, hypotony keratopathy, and hypotony maculopathy) were significantly higher in the 63 µm group (<i>p</i> = 0.011). <b>Conclusions:</b> Although the XEN<sup>®</sup> 63 µm may offer a greater IOP-lowering effect with better complete surgical success, no significant differences were detected compared to the 45 µm device. Hypotony-related complications were higher in the XEN 63 µm, although most of them resolved with conservative management.

Journal of Clinical MedicineVol. 14(10)
Vall d'Hebron Hospital Universitari (ES)
Good health and well-being
Openalex Percentile: Top 18%
Glaucoma and retinal disorders
1.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XEN® Gel Stent in Glaucoma Surgery: One-Year Follow-Up — Manuel Amilburu, Antonio Dou, et al. · Journal of Clinical Medicine (2025) | TGRS Research Map | TGRS