Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed

This article reports the effect of twisted tapes with continuous V-ribs on the thermal performance index characteristics of a heat exchanger tube. Numerical and experimental studies were conducted to investigate the influence of V-rib attack angles (β = 15°, 30°, and 45°) in forward and backward arrangements. This investigation employed 0.9 mm thick, continuous V-rib twisted tapes (CVRTs) made from aluminum sheets formed with a twist ratio of y/w = 4.0. The experimental results indicated that a continuous V-rib twisted tape (CVRT) was more effective in heat transfer improvement than a typical twisted tape (TT). This was due to swirl and longitudinal vortex flows that helped increase flow mixing and reduce boundary layer thickness. Decreased V-rib attack angles (β) led to greater heat transfer enhancement, pressure drop, and thermal performance index values due to the greater turbulent mixing of fluid. The numerical result revealed that a continuous V-rib twisted tape created strong longitudinal vortex flow, especially with higher attack angles. The Turbulent Kinetic Energy (TKE) and core fluid temperature increased with the insertion of CVRTs. Local Nusselt numbers also remained relatively high for heat exchanger tubes with CVRTs. The experimental study illustrated that a tube with a CVRT installed augmented heat transfer. In the experimentally studied cases, a backward arrangement had more heat transfer, a greater friction factor, and a better thermal performance index. Compared to a plain tube, a tube with CVRT installed, having β = 15°, 30°, and 45°, showed 76.8, 71.6, and 66.2% improved heat transfer, respectively. CVRTs with these three β-values, respectively, exhibited higher thermal performance than a TT. Among the investigated CVRTs, the backward-arranged tape with β = 15° offered the maximum thermal performance index, 1.13 at Re = 6000. The results are congruent with the simulation outcomes, hence supporting the CFD analysis.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-05-17
DOI
https://doi.org/10.3390/app15105612
Citations
1
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed

Masafumi Hirota, Smith Eiamsa–ard, Naoki Maruyama, V. Chuwattanakul et al.
1 citations
Applied Sciences
Heat Transfer and Optimization
0.71
article

Heat Transfer Intensification in a Heat Exchanger Tube with Continuous V-Rib Twisted Tapes Installed

Masafumi Hirota, Smith Eiamsa–ard, Naoki Maruyama, V. Chuwattanakul, K. Wongcharee, Paisarn Naphon, Y. Du
article en
1 citations

Abstract

This article reports the effect of twisted tapes with continuous V-ribs on the thermal performance index characteristics of a heat exchanger tube. Numerical and experimental studies were conducted to investigate the influence of V-rib attack angles (β = 15°, 30°, and 45°) in forward and backward arrangements. This investigation employed 0.9 mm thick, continuous V-rib twisted tapes (CVRTs) made from aluminum sheets formed with a twist ratio of y/w = 4.0. The experimental results indicated that a continuous V-rib twisted tape (CVRT) was more effective in heat transfer improvement than a typical twisted tape (TT). This was due to swirl and longitudinal vortex flows that helped increase flow mixing and reduce boundary layer thickness. Decreased V-rib attack angles (β) led to greater heat transfer enhancement, pressure drop, and thermal performance index values due to the greater turbulent mixing of fluid. The numerical result revealed that a continuous V-rib twisted tape created strong longitudinal vortex flow, especially with higher attack angles. The Turbulent Kinetic Energy (TKE) and core fluid temperature increased with the insertion of CVRTs. Local Nusselt numbers also remained relatively high for heat exchanger tubes with CVRTs. The experimental study illustrated that a tube with a CVRT installed augmented heat transfer. In the experimentally studied cases, a backward arrangement had more heat transfer, a greater friction factor, and a better thermal performance index. Compared to a plain tube, a tube with CVRT installed, having β = 15°, 30°, and 45°, showed 76.8, 71.6, and 66.2% improved heat transfer, respectively. CVRTs with these three β-values, respectively, exhibited higher thermal performance than a TT. Among the investigated CVRTs, the backward-arranged tape with β = 15° offered the maximum thermal performance index, 1.13 at Re = 6000. The results are congruent with the simulation outcomes, hence supporting the CFD analysis.

Applied SciencesVol. 15(10)
Mie University (JP), Aichi Institute of Technology (JP), Mahanakorn University of Technology (TH), Srinakharinwirot University (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Openalex Percentile: Top 32%
Heat Transfer and Optimization
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.