Very low-frequency electrical spectroscopy analysis of an ovine renal tissue

This study investigates three main regions of a sheep's kidney: the cortex, outer medulla, and inner medulla. The research introduces an impedance measurement setup designed to assess the electrical characteristics at ultra-low frequencies (below 0.1 Hz), capturing both the real and imaginary components of electrical permittivity and conductivity. The apparatus can evaluate the electrical attributes of samples from the kidney's three specified regions, each measuring 20 mm × 10 mm × 1.5 mm. Parameters such as admittance, electrical permittivity, electrical conductivity, and power factor are determined through mathematical formulas. The primary objective of this study is to address the gaps in low-frequency dielectric property data of kidney tissue, specifically focusing on the energy absorption characteristics of different regions of sheep’s kidney. Findings suggest that these parameters display a pronounced peak at ultra-low frequencies (below 30 mHz). This peak, consistent across various tests, is evident in the graphs representing the imaginary part of the conductivity and the phase of admittance. It signifies a frequency at which the tissue stores a higher amount of electrical energy throughout the tested frequency spectrum. Such characteristic could be pivotal for tissue characterization, diagnostic processes, and therapeutic strategies.

Authors

Institutions

Publication Details

Journal
Discover Applied Sciences
Published
2025-05-19
DOI
https://doi.org/10.1007/s42452-025-07006-0
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Very low-frequency electrical spectroscopy analysis of an ovine renal tissue

Faezeh Azimi Pirsoltan, Mohammad Reza Karafi
Discover Applied Sciences
Electrical and Bioimpedance Tomography
article

Very low-frequency electrical spectroscopy analysis of an ovine renal tissue

Faezeh Azimi Pirsoltan, Mohammad Reza Karafi
article en

Abstract

This study investigates three main regions of a sheep's kidney: the cortex, outer medulla, and inner medulla. The research introduces an impedance measurement setup designed to assess the electrical characteristics at ultra-low frequencies (below 0.1 Hz), capturing both the real and imaginary components of electrical permittivity and conductivity. The apparatus can evaluate the electrical attributes of samples from the kidney's three specified regions, each measuring 20 mm × 10 mm × 1.5 mm. Parameters such as admittance, electrical permittivity, electrical conductivity, and power factor are determined through mathematical formulas. The primary objective of this study is to address the gaps in low-frequency dielectric property data of kidney tissue, specifically focusing on the energy absorption characteristics of different regions of sheep’s kidney. Findings suggest that these parameters display a pronounced peak at ultra-low frequencies (below 30 mHz). This peak, consistent across various tests, is evident in the graphs representing the imaginary part of the conductivity and the phase of admittance. It signifies a frequency at which the tissue stores a higher amount of electrical energy throughout the tested frequency spectrum. Such characteristic could be pivotal for tissue characterization, diagnostic processes, and therapeutic strategies.

Discover Applied SciencesVol. 7(6)
Tarbiat Modares University (IR)
Zero hunger
Openalex Percentile: Top 91%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Very low-frequency electrical spectroscopy analysis of an ovine renal tissue — Faezeh Azimi Pirsoltan, Mohammad Reza Karafi · Discover Applied Sciences (2025) | TGRS Research Map | TGRS