Application of an original fibrin coating in prosthetic hernioplasty in patients with postoperative ventral hernias

Background. The numb er of patients with large postoperative ventral hernias does not tend to decrease. Recurrent hernias after prosthetic hernioplasty occur in 5–25 %. In 1–10 % of patients, the implant becomes infected with the formation of fistulas. The aim. T o develop and apply an original fibrin coating of the implant to accelerate the processes of fibrosis and fixation of the implant in the tissues in large postoperative ventral hernias. Ma t erial and methods. Experimental studies w ere carried out on laboratory animals and bench experiments aimed at developing a fibrin composite for coating mesh implants. Examined and operated on using the technology described by V.I. Belokonev. Eighty patients with large postoperative ventral hernias. Among them there were 37 (46.3 %) men and 43 (53.7 %) women. The patients were examined using standard laboratory and instrumental studies. All patients w ere divided into 2 groups, comparable by gender, age and size of the hernia defect. Group 1 included patients who underwent only V.I. surgery. Belokoneva. The second group was represented by 30 (37.5 %) patients, where after hernia repair and repair of the aponeurosis defect, a fibrin composite was applied to the mesh implant. R esults. The formation of fibrous tissue and the absence of a pronounced inflammatory reaction in the area of application of the fibrin composite within the abdominal wall were detected. In a clinical study, it was found that in group 1 without implant coverage, infiltrates in the area of the postoperative suture occurred in 5 patients (6.3 %). Small fluid accumulations in 3 (3.8 %) patients. Conclusion. A fter using fibrin coating to treat implants, the number of fluid accumulations and infiltrates was lower compared to the main group. No relapses were found in the long-term period up to 1 year.

Authors

Institutions

Publication Details

Journal
Acta Biomedica Scientifica (East Siberian Biomedical Journal)
Published
2025-05-19
DOI
https://doi.org/10.29413/abs.2025-10.2.20
Citations
1
Primary Topic
Hernia repair and management
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of an original fibrin coating in prosthetic hernioplasty in patients with postoperative ventral hernias

V. V. Seroshtanov, S Leontyev, V. G. Lubyansky, D. M. Shtyrov et al.
1 citations
Acta Biomedica Scientifica (East Siberian Biomedical Journal)
Hernia repair and management
2.01
article

Application of an original fibrin coating in prosthetic hernioplasty in patients with postoperative ventral hernias

V. V. Seroshtanov, S Leontyev, V. G. Lubyansky, D. M. Shtyrov, S. A. Podkovyrov
article en
1 citations

Abstract

Background. The numb er of patients with large postoperative ventral hernias does not tend to decrease. Recurrent hernias after prosthetic hernioplasty occur in 5–25 %. In 1–10 % of patients, the implant becomes infected with the formation of fistulas. The aim. T o develop and apply an original fibrin coating of the implant to accelerate the processes of fibrosis and fixation of the implant in the tissues in large postoperative ventral hernias. Ma t erial and methods. Experimental studies w ere carried out on laboratory animals and bench experiments aimed at developing a fibrin composite for coating mesh implants. Examined and operated on using the technology described by V.I. Belokonev. Eighty patients with large postoperative ventral hernias. Among them there were 37 (46.3 %) men and 43 (53.7 %) women. The patients were examined using standard laboratory and instrumental studies. All patients w ere divided into 2 groups, comparable by gender, age and size of the hernia defect. Group 1 included patients who underwent only V.I. surgery. Belokoneva. The second group was represented by 30 (37.5 %) patients, where after hernia repair and repair of the aponeurosis defect, a fibrin composite was applied to the mesh implant. R esults. The formation of fibrous tissue and the absence of a pronounced inflammatory reaction in the area of application of the fibrin composite within the abdominal wall were detected. In a clinical study, it was found that in group 1 without implant coverage, infiltrates in the area of the postoperative suture occurred in 5 patients (6.3 %). Small fluid accumulations in 3 (3.8 %) patients. Conclusion. A fter using fibrin coating to treat implants, the number of fluid accumulations and infiltrates was lower compared to the main group. No relapses were found in the long-term period up to 1 year.

Acta Biomedica Scientifica (East Siberian Biomedical Journal)Vol. 10(2)
Altai State Medical University (RU), Ministry of Health of the Russian Federation (RU), City Hospital (GB)
Openalex Percentile: Top 16%
Hernia repair and management
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.