Supply of MV Island with High-Penetration of Prosumer Renewable Energy Sources

The rapid development of prosumer renewable energy sources (RESs) observed in Poland in recent years causes problems in distribution networks such as current amplitude and voltage asymmetry increases, power and energy loss increases, and reverse power flows, and related are voltage control problems, deterioration of energy quality, etc. Moreover, in the case of planned repair/maintenance works in the network and the need to supply energy consumers in an islanded MV grid, the problem of the correct operation of such a subsystem appears. This occurs when the power production by the prosumers’ energy sources at a given moment exceed the power consumption. In such a case, reverse power flows occur in MV/LV transformers, i.e., from the LV network to the MV network. This causes reverse power flow to the diesel generator, leading to its shutdown and, in extreme cases, to damage. The solution to this problem is to use a mobile system equipped with energy storage in addition to a diesel generator and an LV/MV transformer. An additional problem in the case of using a mobile system (diesel generator) to power an MV island is the islanded MV network grounding. Grid islanding changes the earth fault current and electric shock voltages. In general, MV networks in Poland operate as compensated, i.e., grounding transformers are used, the star point of which is grounded by a compensation choke. Unfortunately, in the case of powering an MV island from a mobile system, there is no real possibility of grounding the star point of the LV/MV transformer used there. This article proposes an algorithm of a diesel generator with an energy storage selection, including electric shock protection requirements verification, for the use in suppling energy via an islanded MV network.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-19
DOI
https://doi.org/10.3390/en18102625
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Supply of MV Island with High-Penetration of Prosumer Renewable Energy Sources

Michał Brodzicki, Mirosław Matusewicz, S. Noske, Zbigniew Lubośny et al.
Energies
Hybrid Renewable Energy Systems
article

Supply of MV Island with High-Penetration of Prosumer Renewable Energy Sources

Michał Brodzicki, Mirosław Matusewicz, S. Noske, Zbigniew Lubośny, Jacek Klucznik, Maciej Klebba, Paweł Bućko, Arkadiusz Frącz
article en

Abstract

The rapid development of prosumer renewable energy sources (RESs) observed in Poland in recent years causes problems in distribution networks such as current amplitude and voltage asymmetry increases, power and energy loss increases, and reverse power flows, and related are voltage control problems, deterioration of energy quality, etc. Moreover, in the case of planned repair/maintenance works in the network and the need to supply energy consumers in an islanded MV grid, the problem of the correct operation of such a subsystem appears. This occurs when the power production by the prosumers’ energy sources at a given moment exceed the power consumption. In such a case, reverse power flows occur in MV/LV transformers, i.e., from the LV network to the MV network. This causes reverse power flow to the diesel generator, leading to its shutdown and, in extreme cases, to damage. The solution to this problem is to use a mobile system equipped with energy storage in addition to a diesel generator and an LV/MV transformer. An additional problem in the case of using a mobile system (diesel generator) to power an MV island is the islanded MV network grounding. Grid islanding changes the earth fault current and electric shock voltages. In general, MV networks in Poland operate as compensated, i.e., grounding transformers are used, the star point of which is grounded by a compensation choke. Unfortunately, in the case of powering an MV island from a mobile system, there is no real possibility of grounding the star point of the LV/MV transformer used there. This article proposes an algorithm of a diesel generator with an energy storage selection, including electric shock protection requirements verification, for the use in suppling energy via an islanded MV network.

EnergiesVol. 18(10)
Gdańsk University of Technology (PL), Polish Naval Academy (PL), Polska Grupa Energetyczna (Poland) (PL)
Openalex Percentile: Top 91%
Hybrid Renewable Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.