Novel Two-Chamber Method for High-Precision TCR Determination of Current Shunts—Part I

The temperature coefficient of resistance (TCR) plays a crucial role in ensuring the functional accuracy of systems. This article examines the determination of TCR for precision current shunts and presents a novel two-chamber method. The method uses a two-chamber setup for high-precision temperature control, which ensures a reduction in measurement uncertainty when determining the TCR. The two-chamber method is applicable for resistance ratios from 0.1 to 10. The advantages of the proposed method are the improvement of the stability of the reference shunt and the reduction of the measurement uncertainty, and thus a more accurate determination of the TCR. In Part I, the influence of the individual parameters on the determination of the measurement uncertainty of the measured TCR is analyzed.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-05-19
DOI
https://doi.org/10.3390/s25103197
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Two-Chamber Method for High-Precision TCR Determination of Current Shunts—Part I

Petar Mostarac, Alan Šala, Roman Malarić, Hrvoje Hegeduš
Sensors
Advanced Sensor Technologies Research
article

Novel Two-Chamber Method for High-Precision TCR Determination of Current Shunts—Part I

Petar Mostarac, Alan Šala, Roman Malarić, Hrvoje Hegeduš
article en

Abstract

The temperature coefficient of resistance (TCR) plays a crucial role in ensuring the functional accuracy of systems. This article examines the determination of TCR for precision current shunts and presents a novel two-chamber method. The method uses a two-chamber setup for high-precision temperature control, which ensures a reduction in measurement uncertainty when determining the TCR. The two-chamber method is applicable for resistance ratios from 0.1 to 10. The advantages of the proposed method are the improvement of the stability of the reference shunt and the reduction of the measurement uncertainty, and thus a more accurate determination of the TCR. In Part I, the influence of the individual parameters on the determination of the measurement uncertainty of the measured TCR is analyzed.

SensorsVol. 25(10)
University of Zagreb (HR)
European Commission
Affordable and clean energy
Openalex Percentile: Top 90%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.