Implementation of a Parametric Ultrasonic Receiver Using Multilayer Lead Zirconate Titanate for a Feasibility Study of an Ultrasonic-Beam-Focused Hearing Aid

We demonstrated that focusing an ultrasonic beam on the eardrum can overcome the high-frequency sensitivity limitations and acoustic distortion of conventional hearing aid receivers. Multilayer PZT was used for an ultrasonic receiver that operates at low voltage and enters the external auditory canal, and a 3 mm radius radiator was designed to radiate the focused parametric acoustic signal to the center of the eardrum based on an acoustic analysis according to the frequency. To this end, an ultrasonic earphone consisting of a radiator attached to multilayer PZT and a 130 kHz parametric ultrasonic modulator was implemented; vibration and sound pressure were measured using a laser vibrometer and a tube-type microphone. The proposed parametric ultrasonic receiver generates an average sound pressure of 70 dB SPL at a frequency of 1~10 kHz with a 10 Vpeak applied voltage; this was implemented to provide a higher output in the range of 5 kHz and above, which is difficult to cover with existing receivers.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-05-19
DOI
https://doi.org/10.3390/app15105679
Citations
1
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation of a Parametric Ultrasonic Receiver Using Multilayer Lead Zirconate Titanate for a Feasibility Study of an Ultrasonic-Beam-Focused Hearing Aid

Jyung Hyun Lee, Ki Woong Seong, Dong Ho Shin, Myoung Nam Kim et al.
1 citations
Applied Sciences
Hearing Loss and Rehabilitation
1.43
article

Implementation of a Parametric Ultrasonic Receiver Using Multilayer Lead Zirconate Titanate for a Feasibility Study of an Ultrasonic-Beam-Focused Hearing Aid

Jyung Hyun Lee, Ki Woong Seong, Dong Ho Shin, Myoung Nam Kim, Jin Ho Cho
article en
1 citations

Abstract

We demonstrated that focusing an ultrasonic beam on the eardrum can overcome the high-frequency sensitivity limitations and acoustic distortion of conventional hearing aid receivers. Multilayer PZT was used for an ultrasonic receiver that operates at low voltage and enters the external auditory canal, and a 3 mm radius radiator was designed to radiate the focused parametric acoustic signal to the center of the eardrum based on an acoustic analysis according to the frequency. To this end, an ultrasonic earphone consisting of a radiator attached to multilayer PZT and a 130 kHz parametric ultrasonic modulator was implemented; vibration and sound pressure were measured using a laser vibrometer and a tube-type microphone. The proposed parametric ultrasonic receiver generates an average sound pressure of 70 dB SPL at a frequency of 1~10 kHz with a 10 Vpeak applied voltage; this was implemented to provide a higher output in the range of 5 kHz and above, which is difficult to cover with existing receivers.

Applied SciencesVol. 15(10)
Kyungpook National University Hospital (KR), Kyungpook National University (KR)
Korea Health Industry Development Institute
Openalex Percentile: Top 19%
Hearing Loss and Rehabilitation
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.