Design and Error Compensation Technology of Dual Frequency Length Measurement System for Space Applications

This paper proposes a miniaturized and lightweight dual frequency laser interferometry measurement system to improve the ground observation accuracy of dual antenna interferometric spaceborne synthetic aperture radar as well as to achieve ultra-high precision radar baseline measurement. The error model for the measurement system is then established. The impact mechanism of numerous faults thereafter is studied, and the phase drift error induced by changes in signal amplitude is identified as the primary system defect. To mitigate the impact of the mistake used for real-time compensation, a phase-amplitude detection circuit was created by combining digital phase measurement methods. Finally, the ranging performance of the system is experimentally verified. The results show that the dual-frequency laser interferometric measurement system has a volume of 120 mm x 20 mm x 80 mm, meeting the requirements of miniaturization and lightweight design. The relative displacement resolution at 10 meters can reach 0.1 µm, and the peak displacement measurement error is better than 0.2 µm.

Authors

Institutions

Publication Details

Published
2024-11-21
DOI
https://doi.org/10.1109/aisomt64170.2024.10992163
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Error Compensation Technology of Dual Frequency Length Measurement System for Space Applications

Ziqi Yin, Chunfang Zhao, Jiale Wu, Jing Li et al.
1 links
Optical Systems and Laser Technology
article

Design and Error Compensation Technology of Dual Frequency Length Measurement System for Space Applications

Ziqi Yin, Chunfang Zhao, Jiale Wu, Jing Li, Mingyang Li, Lifeng Chen, Hongxing Yang
article en

Abstract

This paper proposes a miniaturized and lightweight dual frequency laser interferometry measurement system to improve the ground observation accuracy of dual antenna interferometric spaceborne synthetic aperture radar as well as to achieve ultra-high precision radar baseline measurement. The error model for the measurement system is then established. The impact mechanism of numerous faults thereafter is studied, and the phase drift error induced by changes in signal amplitude is identified as the primary system defect. To mitigate the impact of the mistake used for real-time compensation, a phase-amplitude detection circuit was created by combining digital phase measurement methods. Finally, the ranging performance of the system is experimentally verified. The results show that the dual-frequency laser interferometric measurement system has a volume of 120 mm x 20 mm x 80 mm, meeting the requirements of miniaturization and lightweight design. The relative displacement resolution at 10 meters can reach 0.1 µm, and the peak displacement measurement error is better than 0.2 µm.

Harbin Institute of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 72%
Optical Systems and Laser Technology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.