Fault Compensations in Compensated Distribution Networks to Mitigate Powerline Bushfires Using a Backstepping Nonsingular Integral Sliding Mode Controller

A hybrid nonlinear control scheme combining the backstepping and nonsingular integral terminal sliding mode control schemes is presented for the residual current compensation (RCC) inverter in a compensated distribution network. The main control objective is to swiftly compensate fault characteristics to avoid powerline bushfire risks in bushfire-prone areas. The proposed control scheme is developed considering a second-order dynamical model of RCC inverters, comprising the neutral voltage and neutral current dynamics. The new control scheme is developed in a way that the neutral voltage tracking error is considered as the basis for developing the virtual control input for tracking the neutral current. At the same time, both tracking errors are considered to determine the nonsingular integral terminal sliding surface based on which the overall control law is derived for the RCC inverter. The performance of the proposed controller is evaluated in terms of compensating fault characteristics and compared with a nonsingular integral terminal sliding mode controller.

Authors

Institutions

Publication Details

Published
2024-12-04
DOI
https://doi.org/10.1109/spies63782.2024.10983588
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fault Compensations in Compensated Distribution Networks to Mitigate Powerline Bushfires Using a Backstepping Nonsingular Integral Sliding Mode Controller

Amanullah Maung Than Oo, M. A. Mahmud, Tushar Kanti Roy
Power System Optimization and Stability
article

Fault Compensations in Compensated Distribution Networks to Mitigate Powerline Bushfires Using a Backstepping Nonsingular Integral Sliding Mode Controller

Amanullah Maung Than Oo, M. A. Mahmud, Tushar Kanti Roy
article en

Abstract

A hybrid nonlinear control scheme combining the backstepping and nonsingular integral terminal sliding mode control schemes is presented for the residual current compensation (RCC) inverter in a compensated distribution network. The main control objective is to swiftly compensate fault characteristics to avoid powerline bushfire risks in bushfire-prone areas. The proposed control scheme is developed considering a second-order dynamical model of RCC inverters, comprising the neutral voltage and neutral current dynamics. The new control scheme is developed in a way that the neutral voltage tracking error is considered as the basis for developing the virtual control input for tracking the neutral current. At the same time, both tracking errors are considered to determine the nonsingular integral terminal sliding surface based on which the overall control law is derived for the RCC inverter. The performance of the proposed controller is evaluated in terms of compensating fault characteristics and compared with a nonsingular integral terminal sliding mode controller.

Flinders University (AU), Macquarie University (AU)
Climate action
Openalex Percentile: Top 72%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.