A Reconfigurable 0.69-1.02nJ/Classification Biomedical AI Processor for Intelligent Health Monitoring Devices

Ultra-low-power biomedical AI processors are crucial for effective intelligent health monitoring systems (HMSs) in wearable devices. Traditional HMSs rely on feature-based methods [1], [2] that necessitate human intervention for pre-extract features before classification. Unfortunately, this approach often leads to poor accuracy <90%) and can be time-consuming. Recently, end-to-end neural networks (NNs) [3]–[8] have demonstrated promising results by directly processing original ExG (EEG, ECG, EMG, etc.) signals for classification. This method circumvents the limitations imposed by human expertise and achieves higher accuracy. Yet, the implementation of more complex NNs brings forth new challenges, as illustrated in Fig. 1: 1) prior reconfigurable HMSs underutilize memory resources (~8.9% utilization in the EEG mode of [7]) due to the need for multiple NNs of varying sizes for different detection modes; 2) frequent memory access significantly dominates the power consumption of AI systems; 3) the presence of redundant bio-information in ExG signals results in unnecessary computational energy dissipation.

Authors

Institutions

Publication Details

Published
2025-04-13
DOI
https://doi.org/10.1109/cicc63670.2025.10983210
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Reconfigurable 0.69-1.02nJ/Classification Biomedical AI Processor for Intelligent Health Monitoring Devices

Yuheng Wang, Chi‐Hang Chan, R. P. Martins, Yan Zhu et al.
ECG Monitoring and Analysis
article

A Reconfigurable 0.69-1.02nJ/Classification Biomedical AI Processor for Intelligent Health Monitoring Devices

Yuheng Wang, Chi‐Hang Chan, R. P. Martins, Yan Zhu, Minglei Zhang, Zijian Wang, Yuanzhe Zhao
article en

Abstract

Ultra-low-power biomedical AI processors are crucial for effective intelligent health monitoring systems (HMSs) in wearable devices. Traditional HMSs rely on feature-based methods [1], [2] that necessitate human intervention for pre-extract features before classification. Unfortunately, this approach often leads to poor accuracy <90%) and can be time-consuming. Recently, end-to-end neural networks (NNs) [3]–[8] have demonstrated promising results by directly processing original ExG (EEG, ECG, EMG, etc.) signals for classification. This method circumvents the limitations imposed by human expertise and achieves higher accuracy. Yet, the implementation of more complex NNs brings forth new challenges, as illustrated in Fig. 1: 1) prior reconfigurable HMSs underutilize memory resources (~8.9% utilization in the EEG mode of [7]) due to the need for multiple NNs of varying sizes for different detection modes; 2) frequent memory access significantly dominates the power consumption of AI systems; 3) the presence of redundant bio-information in ExG signals results in unnecessary computational energy dissipation.

University of Macau (MO)
Openalex Percentile: Top 81%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.