A 0.7pA<sub>rms</sub> Electrochemical Readout IC for Continuous Monitoring of Antibody Biologics in Upstream Biomanufacturing

Biologics are antibodies produced by genetically engineered cells and are widely used in therapeutic applications. Examples include pembrolizumab (Keytruda) and atezolizumab (Tecentriq), both employed in cancer immunotherapy as checkpoint inhibitors to restore T-cell immune responses against tumor cells [1]–[2]. These biologics are produced by engineered cells in bioreactors, followed by extraction, filtration, purification, and separation, before being packaged into drug vials and shipped to hospitals for patient treatment. The production of monoclonal antibodies by cells is highly sensitive to the bioreactor environment, making it essential to integrate process analytical technologies (PAT) for closed-loop, real-time adjustments [3]–[4]. Parameters such as pH, ion concentrations, dissolved oxygen, carbon dioxide, pressure, and cell density, among others, are routinely monitored through in-line (using sensor probes immersed directly in the bioreactor) and on-line (utilizing a bypass channel that circulates medium back to the tank) approaches with discrete sensors [5] (Fig. 1). Recent trends have focused on leveraging integrated circuit (IC) solutions for system miniaturization and enhanced functionality. For instance, [6] demonstrates the first single IC with multi-channel capability, enabling monitoring of O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>, pH, oxidation-reduction potential (ORP), temperature, and glucose levels. However, no current technology can directly and continuously quantify the concentration and quality of the produced biologics in real-time within the bioreactor. These critical measurements still rely on off-line methods such as immunoassays and mass spectrometry, which are time-consuming and not suitable for real-time process control.

Authors

Institutions

Publication Details

Published
2025-04-13
DOI
https://doi.org/10.1109/cicc63670.2025.10983591
Primary Topic
Nanofabrication and Lithography Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 0.7pArms Electrochemical Readout IC for Continuous Monitoring of Antibody Biologics in Upstream Biomanufacturing

Ya-Chen Tsai, Hung-Yu Hou, Wei Cho Foo, Yan-Ting Hsiao et al.
Nanofabrication and Lithography Techniques
article

A 0.7pArms Electrochemical Readout IC for Continuous Monitoring of Antibody Biologics in Upstream Biomanufacturing

Ya-Chen Tsai, Hung-Yu Hou, Wei Cho Foo, Yan-Ting Hsiao, Jun-Chau Chien
article en

Abstract

Biologics are antibodies produced by genetically engineered cells and are widely used in therapeutic applications. Examples include pembrolizumab (Keytruda) and atezolizumab (Tecentriq), both employed in cancer immunotherapy as checkpoint inhibitors to restore T-cell immune responses against tumor cells [1]–[2]. These biologics are produced by engineered cells in bioreactors, followed by extraction, filtration, purification, and separation, before being packaged into drug vials and shipped to hospitals for patient treatment. The production of monoclonal antibodies by cells is highly sensitive to the bioreactor environment, making it essential to integrate process analytical technologies (PAT) for closed-loop, real-time adjustments [3]–[4]. Parameters such as pH, ion concentrations, dissolved oxygen, carbon dioxide, pressure, and cell density, among others, are routinely monitored through in-line (using sensor probes immersed directly in the bioreactor) and on-line (utilizing a bypass channel that circulates medium back to the tank) approaches with discrete sensors [5] (Fig. 1). Recent trends have focused on leveraging integrated circuit (IC) solutions for system miniaturization and enhanced functionality. For instance, [6] demonstrates the first single IC with multi-channel capability, enabling monitoring of O<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf>, pH, oxidation-reduction potential (ORP), temperature, and glucose levels. However, no current technology can directly and continuously quantify the concentration and quality of the produced biologics in real-time within the bioreactor. These critical measurements still rely on off-line methods such as immunoassays and mass spectrometry, which are time-consuming and not suitable for real-time process control.

University of California, Berkeley (US)
National Science Foundation
Openalex Percentile: Top 90%
Nanofabrication and Lithography Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 0.7pA<sub>rms</sub> Electrochemical Readout IC for Continuous Monitoring of Antibody Biologics in Upstream Biomanufacturing — Ya-Chen Tsai, Hung-Yu Hou, et al. · (2025) | TGRS Research Map | TGRS