Customization Theory of a Set of Optimal Calibration Standards for the Six-Port Reflectometer Based on Power Measurement Errors

A design theory of optimal calibration standards for a six-port reflectometer based on the power measurement error is proposed here. Rather than general, the calibration standards are specially customized corresponding to the practically utilized six-port reflectometer system itself. The basic logic is the objective stability of the six-port reflectometer in representing a reflection coefficient (Γ). Treated as devices under test, the calibration standards are customized as optimal corresponding to a power measurement condition during long-term and repeated usage. The availability of the customization is firstly verified in simulation. Γ around the entire Smith chart are calculated after different sets of calibration standards, respectively. The customized calibration is more accurate and distributes more concentrated. The effect is especially obvious for Γ with 0 dB to −15 dB in magnitude. A practical six-port reflectometer system is built and performed as the proposed method. By the replacement of the optimal calibration standards, the average of the worst-case range under long-term power measurement error is reduced from ±5.22 dB to ±3.50 dB in magnitude and from ±31.17° to ±19.18° in phase for |Γ| @−13 dB. More importantly, the probability with error larger than 15% in magnitude (|Γ| < −11.8 dB or |Γ| > −14.4 dB) is decreased from 27% to 16%. The proposed method is theoretically verified for a general working bandwidth of the built six-port (11.7%@2.55 GHz). The theory can be a plug-and-play and supplementary rule for most instrument based on multiport measurement to enhance the reliability and extend the lifespan.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3571156
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Customization Theory of a Set of Optimal Calibration Standards for the Six-Port Reflectometer Based on Power Measurement Errors

Pingle Hao, Sen Yan, Penghao Feng, Binke Huang
IEEE Transactions on Instrumentation and Measurement
Microwave and Dielectric Measurement Techniques
article

Customization Theory of a Set of Optimal Calibration Standards for the Six-Port Reflectometer Based on Power Measurement Errors

Pingle Hao, Sen Yan, Penghao Feng, Binke Huang
article en

Abstract

A design theory of optimal calibration standards for a six-port reflectometer based on the power measurement error is proposed here. Rather than general, the calibration standards are specially customized corresponding to the practically utilized six-port reflectometer system itself. The basic logic is the objective stability of the six-port reflectometer in representing a reflection coefficient (Γ). Treated as devices under test, the calibration standards are customized as optimal corresponding to a power measurement condition during long-term and repeated usage. The availability of the customization is firstly verified in simulation. Γ around the entire Smith chart are calculated after different sets of calibration standards, respectively. The customized calibration is more accurate and distributes more concentrated. The effect is especially obvious for Γ with 0 dB to −15 dB in magnitude. A practical six-port reflectometer system is built and performed as the proposed method. By the replacement of the optimal calibration standards, the average of the worst-case range under long-term power measurement error is reduced from ±5.22 dB to ±3.50 dB in magnitude and from ±31.17° to ±19.18° in phase for |Γ| @−13 dB. More importantly, the probability with error larger than 15% in magnitude (|Γ| < −11.8 dB or |Γ| > −14.4 dB) is decreased from 27% to 16%. The proposed method is theoretically verified for a general working bandwidth of the built six-port (11.7%@2.55 GHz). The theory can be a plug-and-play and supplementary rule for most instrument based on multiport measurement to enhance the reliability and extend the lifespan.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, China Scholarship Council
Affordable and clean energy
Openalex Percentile: Top 91%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.