NH₃-Targeted Corrosion-Resistant MEMS Calorimetric Flow Sensor Based on Parylene C

This letter presents a corrosion-resistant MEMS calorimetric flow sensor that addresses reliability challenges in ammonia (NH<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>) flow measurement. The employment of Parylene C anti-corrosion coating extends the sensor’s stability in 25 wt% ammonia solution to over 168 hours, demonstrating enhanced resistance to alkaline corrosion. Additionally, compared with suspended membrane designs, the adoption of porous silicon thermal isolation structure reduces the zero-flow voltage difference when measuring NH<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> versus N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> from 2.02%FS to 0.07%FS, enabling mass production using an N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>-calibration scheme. The experimental results demonstrate the sensor’s potential for replacing capillary-based flow sensors in semiconductor manufacturing.

Authors

Institutions

Publication Details

Journal
IEEE Electron Device Letters
Published
2025-05-19
DOI
https://doi.org/10.1109/led.2025.3571366
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

NH₃-Targeted Corrosion-Resistant MEMS Calorimetric Flow Sensor Based on Parylene C

Jifang Tao, Yuhan Liu, Wei Tian, Zhanmang Liao et al.
2 links
IEEE Electron Device Letters
Gas Sensing Nanomaterials and Sensors
article

NH₃-Targeted Corrosion-Resistant MEMS Calorimetric Flow Sensor Based on Parylene C

Jifang Tao, Yuhan Liu, Wei Tian, Zhanmang Liao, Jiale Kang, Yuzhe Lin
article en

Abstract

This letter presents a corrosion-resistant MEMS calorimetric flow sensor that addresses reliability challenges in ammonia (NH<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub>) flow measurement. The employment of Parylene C anti-corrosion coating extends the sensor’s stability in 25 wt% ammonia solution to over 168 hours, demonstrating enhanced resistance to alkaline corrosion. Additionally, compared with suspended membrane designs, the adoption of porous silicon thermal isolation structure reduces the zero-flow voltage difference when measuring NH<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> versus N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> from 2.02%FS to 0.07%FS, enabling mass production using an N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>-calibration scheme. The experimental results demonstrate the sensor’s potential for replacing capillary-based flow sensors in semiconductor manufacturing.

IEEE Electron Device LettersVol. 46(7)
Qingdao University (CN), Shandong University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 91%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.