Performance Analysis of In-Beam PET Range Verification System for Carbon Ion Beams

The Superconducting Ion Gantry (SIG) project aims to develop a reliable in vivo Range Verification System (RVS) for integration into a multi-ion gantry. The project includes researching, designing, and testing the system’s fundamental components. Based on RVS element performance, the ultimate goal is to design a full system that meets clinical requirements. Therefore, in this study, we present the performance evaluation of a small in-beam Positron Emission Tomography (PET) prototype for carbon ion irradiations. The experimental setup consists of 6 PET modules arranged in hexagonal geometry (3 vs 3 partial ring configuration), with a radius of 98 mm. Each detector block features 16×16 pixels, 3.2 mm pitch of segmented Lutetium Fine Silicate (LFS) scintillator crystals, coupled one-to-one to Silicon Photomultiplier (SiPM) matrices. Homogeneous phantoms were irradiated with two monoenergetic beams at different energies at CNAO (Italian National Center of Oncological Hadron Therapy). Data were acquired online during the irradiation. For this study, images are reconstructed from the irradiation in the pauses between beam spills (inter-spill). The performance analysis was focused on evaluating the stability of range difference estimation considering different subsets of coincidence events along the beam irradiation.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Published
2025-05-19
DOI
https://doi.org/10.1109/trpms.2025.3571308
Citations
2
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Analysis of In-Beam PET Range Verification System for Carbon Ion Beams

M. Pullia, Emanuele Data, M. Donetti, S. Giordanengo et al.
2 citations
IEEE Transactions on Radiation and Plasma Medical Sciences
Radiation Effects in Electronics
1.46
article

Performance Analysis of In-Beam PET Range Verification System for Carbon Ion Beams

M. Pullia, Emanuele Data, M. Donetti, S. Giordanengo, V. Ferrero, Mahdi Hosseini, F. Pennazio, P. Cerello, Félix Más Milián, M. Fadavi Mazinani, J. Werner, Elisa Fiorina, Diango Montalvan Olivares, Davide Bersani, R. Cirio, M. Rafecas, Seyed Faramarz Ranjbar, R. Sacchi A. Vignati
article en
2 citations

Abstract

The Superconducting Ion Gantry (SIG) project aims to develop a reliable in vivo Range Verification System (RVS) for integration into a multi-ion gantry. The project includes researching, designing, and testing the system’s fundamental components. Based on RVS element performance, the ultimate goal is to design a full system that meets clinical requirements. Therefore, in this study, we present the performance evaluation of a small in-beam Positron Emission Tomography (PET) prototype for carbon ion irradiations. The experimental setup consists of 6 PET modules arranged in hexagonal geometry (3 vs 3 partial ring configuration), with a radius of 98 mm. Each detector block features 16×16 pixels, 3.2 mm pitch of segmented Lutetium Fine Silicate (LFS) scintillator crystals, coupled one-to-one to Silicon Photomultiplier (SiPM) matrices. Homogeneous phantoms were irradiated with two monoenergetic beams at different energies at CNAO (Italian National Center of Oncological Hadron Therapy). Data were acquired online during the irradiation. For this study, images are reconstructed from the irradiation in the pauses between beam spills (inter-spill). The performance analysis was focused on evaluating the stability of range difference estimation considering different subsets of coincidence events along the beam irradiation.

IEEE Transactions on Radiation and Plasma Medical SciencesVol. 10(1)
Istituto Nazionale di Fisica Nucleare (IT), Istituto Nazionale di Fisica Nucleare, Sezione di Torino (IT), National Center for Oncological Hadrontherapy (IT), Becker Technologies (Germany) (DE), Istituto Nazionale di Fisica Nucleare, Sezione di Pisa (IT), University of Turin (IT), University of Lübeck (DE)
Openalex Percentile: Top 17%
Radiation Effects in Electronics
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.