High-Sensitivity Vector Magnetometer Based on Mach–Zehnder Interferometer Combined With Magnetostrictive Material

A highly sensitive vector magnetometer based on Mach-Zehnder interferometer (MZI) combined with Terfenol-D rod was proposed. Firstly, a single-mode fiber (SMF) without a coating layer is directly tapered to form an MZI, named MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>. Due to the small cross-sectional area of MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>, its strain sensitivity was experimentally obtained to be as high as -64.04 pm/le. Terfenol-D exhibits good stretchability under the influence of the magnetic field (MF), and the direction of stretchability is related to the direction of the MF. MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> is pasted on the Terfenol-D rod. MF causes expansion and contraction of Terfenol-D rod, which is equal to acting an axial strain on MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>, indirectly achieving the MF measurement. The experimental outcomes indicate that the sensitivities of MF intensity and direction of MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> are -0.221 nm/mT and 0.0712 nm/°. To further enhance its sensitivity, we connect MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, which has a similar structure and free spectrum range to MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>, in series with MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> to form a vernier effect (VE) sensor S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> for MF vector measurement. The experimental findings show that the MF intensity sensitivity of S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> is as high as -1.360 nm/mT at the 0° direction, and the MF direction sensitivity of S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> is 0.4981 nm/° at 20 mT, which enhances the MF intensity and direction sensitivities of MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> by 6.2 times and 7.0 times. S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> also has excellent measurement repeatability and stability. This sensor has the advantages of simple structure, easy fabrication, repeatable structure, and high economic benefits, providing a powerful solution for MF vector measurement.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-05-19
DOI
https://doi.org/10.1109/jsen.2025.3566017
Primary Topic
Magneto-Optical Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Sensitivity Vector Magnetometer Based on Mach–Zehnder Interferometer Combined With Magnetostrictive Material

Simei Sun, Chao Jiang, Yansheng Li, Xinglin Tong et al.
IEEE Sensors Journal
Magneto-Optical Properties and Applications
article

High-Sensitivity Vector Magnetometer Based on Mach–Zehnder Interferometer Combined With Magnetostrictive Material

Simei Sun, Chao Jiang, Yansheng Li, Xinglin Tong, Xiaoshan Guo
article en

Abstract

A highly sensitive vector magnetometer based on Mach-Zehnder interferometer (MZI) combined with Terfenol-D rod was proposed. Firstly, a single-mode fiber (SMF) without a coating layer is directly tapered to form an MZI, named MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>. Due to the small cross-sectional area of MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>, its strain sensitivity was experimentally obtained to be as high as -64.04 pm/le. Terfenol-D exhibits good stretchability under the influence of the magnetic field (MF), and the direction of stretchability is related to the direction of the MF. MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> is pasted on the Terfenol-D rod. MF causes expansion and contraction of Terfenol-D rod, which is equal to acting an axial strain on MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>, indirectly achieving the MF measurement. The experimental outcomes indicate that the sensitivities of MF intensity and direction of MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> are -0.221 nm/mT and 0.0712 nm/°. To further enhance its sensitivity, we connect MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, which has a similar structure and free spectrum range to MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub>, in series with MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> to form a vernier effect (VE) sensor S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> for MF vector measurement. The experimental findings show that the MF intensity sensitivity of S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> is as high as -1.360 nm/mT at the 0° direction, and the MF direction sensitivity of S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> is 0.4981 nm/° at 20 mT, which enhances the MF intensity and direction sensitivities of MZI<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> by 6.2 times and 7.0 times. S<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sub> also has excellent measurement repeatability and stability. This sensor has the advantages of simple structure, easy fabrication, repeatable structure, and high economic benefits, providing a powerful solution for MF vector measurement.

IEEE Sensors JournalVol. 25(13)
Wuhan University of Technology (CN), Hubei Normal University (CN)
National Natural Science Foundation of China, National Natural Science Foundation of China-Guangdong Joint Fund
Affordable and clean energy
Openalex Percentile: Top 91%
Magneto-Optical Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.