Deformation of laser reflection surface in primary calibration of accelerometers

Abstract In international comparisons of single-ended (SE) accelerometer calibrations, a significant issue has been the relative motion between the laser measurement position and the reference surface of the accelerometer. One cause of this relative motion is deformation of the adapter to which the accelerometer is attached. In this study, to quantify and elucidate the mechanism of this adapter deformation, multipoint vibration measurements were conducted using multiple adapters with different load masses, Young’s moduli, and thicknesses. The results demonstrated that the magnitude of the deformation is proportional to the square of the vibration frequency, proportional to the load mass, inversely proportional to the Young’s modulus, and inversely correlated with the thickness. These findings indicate that the quasi-static deformation induced by the inertial force of the accelerometer is the primary cause of adapter deformation. For a stainless steel adapter combined with a Brüel & Kjær type 8305-001 accelerometer, a radial deformation factor of (−1 to −1.7)%/mm was measured at 20 kHz. These findings contribute to ensuring international equivalence in the primary calibration of SE accelerometers.

Authors

Institutions

Publication Details

Journal
Metrologia
Published
2025-05-19
DOI
https://doi.org/10.1088/1681-7575/adda4f
Citations
1
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deformation of laser reflection surface in primary calibration of accelerometers

Hideaki Nozato, Akira Hasegawa, Tomofumi Shimoda, Wataru Kokuyama
1 citations
Metrologia
Advanced Measurement and Metrology Techniques
0.71
article

Deformation of laser reflection surface in primary calibration of accelerometers

Hideaki Nozato, Akira Hasegawa, Tomofumi Shimoda, Wataru Kokuyama
article en
1 citations

Abstract

Abstract In international comparisons of single-ended (SE) accelerometer calibrations, a significant issue has been the relative motion between the laser measurement position and the reference surface of the accelerometer. One cause of this relative motion is deformation of the adapter to which the accelerometer is attached. In this study, to quantify and elucidate the mechanism of this adapter deformation, multipoint vibration measurements were conducted using multiple adapters with different load masses, Young’s moduli, and thicknesses. The results demonstrated that the magnitude of the deformation is proportional to the square of the vibration frequency, proportional to the load mass, inversely proportional to the Young’s modulus, and inversely correlated with the thickness. These findings indicate that the quasi-static deformation induced by the inertial force of the accelerometer is the primary cause of adapter deformation. For a stainless steel adapter combined with a Brüel & Kjær type 8305-001 accelerometer, a radial deformation factor of (−1 to −1.7)%/mm was measured at 20 kHz. These findings contribute to ensuring international equivalence in the primary calibration of SE accelerometers.

MetrologiaVol. 62(3)
National Institute of Advanced Industrial Science and Technology (JP)
Openalex Percentile: Top 32%
Advanced Measurement and Metrology Techniques
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Deformation of laser reflection surface in primary calibration of accelerometers — Hideaki Nozato, Akira Hasegawa, et al. · Metrologia (2025) | TGRS Research Map | TGRS