Evaluation of dose distribution and shielding efficiency in portable intraoral x-ray device

Portable intraoral x-ray devices are widely used in dental radiology due to their affordability and convenience. However, concerns about radiation exposure to operators from scattered radiation are rising. This study uses an anthropomorphic phantom and a radiation detector to measure the ambient dose equivalent rate caused by secondary scatter radiation. Measurements were taken at different angles, distances, and heights, both with and without a shielding disk (provided by the portable device). The results show that the shielding disk reduces radiation exposure by up to 94%, but its effectiveness varies depending on the operator's position. Sensitive areas, such as the gonads and eye lenses, can receive higher doses under certain conditions. Annual dose estimations revealed that exposure could exceed 1 mSv in some cases, highlighting the need for operators to wear personal dosimeters and follow safety protocols. Recommendations include keeping a safe distance, shielding disk must be used, and avoid to tilt the x-ray unit. This study underscores the importance of properly using and regulating portable x-ray devices to ensure operator safety while maintaining their practical benefits.

Authors

Institutions

Publication Details

Journal
Journal of Radiological Protection
Published
2025-05-19
DOI
https://doi.org/10.1088/1361-6498/adda55
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of dose distribution and shielding efficiency in portable intraoral x-ray device

Ana Cecilia Ruiz-Imbert, A Hidalgo Rivas, Lucía Barba Ramírez, Jeffrey Mendez et al.
Journal of Radiological Protection
Advanced Radiotherapy Techniques
article

Evaluation of dose distribution and shielding efficiency in portable intraoral x-ray device

Ana Cecilia Ruiz-Imbert, A Hidalgo Rivas, Lucía Barba Ramírez, Jeffrey Mendez, Gerardo Noguera Vega
article en

Abstract

Portable intraoral x-ray devices are widely used in dental radiology due to their affordability and convenience. However, concerns about radiation exposure to operators from scattered radiation are rising. This study uses an anthropomorphic phantom and a radiation detector to measure the ambient dose equivalent rate caused by secondary scatter radiation. Measurements were taken at different angles, distances, and heights, both with and without a shielding disk (provided by the portable device). The results show that the shielding disk reduces radiation exposure by up to 94%, but its effectiveness varies depending on the operator's position. Sensitive areas, such as the gonads and eye lenses, can receive higher doses under certain conditions. Annual dose estimations revealed that exposure could exceed 1 mSv in some cases, highlighting the need for operators to wear personal dosimeters and follow safety protocols. Recommendations include keeping a safe distance, shielding disk must be used, and avoid to tilt the x-ray unit. This study underscores the importance of properly using and regulating portable x-ray devices to ensure operator safety while maintaining their practical benefits.

Journal of Radiological ProtectionVol. 45(2)
University of Talca (CL), Catholic University of the Maule (CL), Universidad de Costa Rica (CR), Business University of Costa Rica (CR), Universidad Libre de Costa Rica (CR), Hospital Regional de Talca (CL)
Openalex Percentile: Top 87%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.