Digital Butterworth filter as preprocessing method for implementing Raman spectroscopy as an analytical method in downstream processing of biopharmaceuticals

For implementing Raman spectroscopy as an analytical method in downstream processing, extracting molecular information related to biopharmaceuticals is still challenging due to spectral variations caused by spectrometer, setup and fluorescence. This study explores the potential of the Butterworth filter as a preprocessing method for baseline correction and noise reduction in Raman spectra. We first investigate the Butterworth highpass filter's working principle and its optimization by introducing disturbances to spectral baselines and assessing the cutoff frequency ω<sub>c</sub>'s effect on minimizing baseline variations and enhancing the linear correlation (r<sup>2</sup>) between Raman signals and protein concentrations. The optimal ω<sub>c</sub> range (0.004 to 0.008 cm) yields an r<sup>2</sup>≥0.85, outperforming the Savitzky-Golay derivative filter's 0.68. Further, we explore a Butterworth bandpass filter, adjusting low and high cutoff frequencies, showing an 11.6-15 % improvement in r<sup>2</sup> over the highpass design. Our results suggest the necessity of specific cutoff frequency selection when applying the bandpass design to the Raman spectra of individual protein molecules and the method for this selection is discussed. By applying the optimization outputs, we developed chemometric models linking Critical Quality Attributes to the Raman data preprocessed by the Butterworth bandpass filter, covering concentrations up to 25.6 mg/mL for a biopharmaceutical immunoglobulin G (IgG) antibody and 4.2 mg/mL for Transferrin. When validated in Cation Exchange Chromatography runs with gradient lengths of 5 and 10 column volume for in-line predictions, the models show high predictability, achieving a coefficient of determination R<sup>2</sup> of 0.99 for IgG and 0.95 for Transferrin.

Authors

Institutions

Publication Details

Journal
Journal of Chromatography A
Published
2025-05-19
DOI
https://doi.org/10.1016/j.chroma.2025.466069
Citations
3
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
4.90
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital Butterworth filter as preprocessing method for implementing Raman spectroscopy as an analytical method in downstream processing of biopharmaceuticals

Joey Studts, Robin Schiemer, Matthias Franzreb, Jingyi Chen et al.
3 citations
Journal of Chromatography A
Spectroscopy Techniques in Biomedical and Chemical Research
4.90
article

Digital Butterworth filter as preprocessing method for implementing Raman spectroscopy as an analytical method in downstream processing of biopharmaceuticals

Joey Studts, Robin Schiemer, Matthias Franzreb, Jingyi Chen, Gang Wang, Jason Reyes
article en
3 citations

Abstract

For implementing Raman spectroscopy as an analytical method in downstream processing, extracting molecular information related to biopharmaceuticals is still challenging due to spectral variations caused by spectrometer, setup and fluorescence. This study explores the potential of the Butterworth filter as a preprocessing method for baseline correction and noise reduction in Raman spectra. We first investigate the Butterworth highpass filter's working principle and its optimization by introducing disturbances to spectral baselines and assessing the cutoff frequency ω<sub>c</sub>'s effect on minimizing baseline variations and enhancing the linear correlation (r<sup>2</sup>) between Raman signals and protein concentrations. The optimal ω<sub>c</sub> range (0.004 to 0.008 cm) yields an r<sup>2</sup>≥0.85, outperforming the Savitzky-Golay derivative filter's 0.68. Further, we explore a Butterworth bandpass filter, adjusting low and high cutoff frequencies, showing an 11.6-15 % improvement in r<sup>2</sup> over the highpass design. Our results suggest the necessity of specific cutoff frequency selection when applying the bandpass design to the Raman spectra of individual protein molecules and the method for this selection is discussed. By applying the optimization outputs, we developed chemometric models linking Critical Quality Attributes to the Raman data preprocessed by the Butterworth bandpass filter, covering concentrations up to 25.6 mg/mL for a biopharmaceutical immunoglobulin G (IgG) antibody and 4.2 mg/mL for Transferrin. When validated in Cation Exchange Chromatography runs with gradient lengths of 5 and 10 column volume for in-line predictions, the models show high predictability, achieving a coefficient of determination R<sup>2</sup> of 0.99 for IgG and 0.95 for Transferrin.

Journal of Chromatography AVol. 1756
Karlsruhe Institute of Technology (DE), Boehringer Ingelheim (Germany) (DE)
Zero hunger
Openalex Percentile: Top 5%
Spectroscopy Techniques in Biomedical and Chemical Research
4.90
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.