Tricaprylylmethylammonium chloride-enhanced high sensitivity potentiometric sensor for iodide assessment in antiseptic solutions

A high-sensitivity potentiometric iodide sensor was fabricated using tricaprylylmethylammonium chloride (TCMACl) as an ion exchanger incorporated into a PVC matrix. The constructed electrode demonstrated high performance characteristics toward I − ion, with a Nernstian slope of −59.2 ± 0.17 mV/decade, a wide dynamic working range extending from 5 × 10 −7 to 5 × 10 −2 M, and a low detection limit of 5.0 × 10 −7 M. The proposed electrode was characterized by its fast response time of 4 s toward the analyte during calibration and the evaluation of iodide in samples. The surface of the prepared membrane was examined using SEM-EDX analysis, supported by mapping, and the stability of TCMACl in the membrane was studied using a mass loss method. The responsive sensor successfully determined the iodide concentration in antiseptic pharmaceutical drugs, achieving an average recovery of 96 % with a relative standard deviation (RSD) of 1.81 %. Additionally, the constructed sensor was applied as an indicator electrode in the potentiometric titration of AgNO 3 against KI solution. • A high-sensitivity iodide sensor was successfully developed using tricaprylylmethyl ammonium chloride as ion-exchanger. • Mapping demonstrated the iodide distribution on the electrode surface. • The iodide sensor revealed a faster response time of 4 s than other previously reported, highlighting its potential for real-time monitoring applications. • The developed sensor successfully determined the iodide concentration in antiseptic pharmaceutical drugs and was applied as an indicator electrode in the potentiometric titration of AgNO₃ against KI solution.

Authors

Institutions

Publication Details

Journal
Results in Chemistry
Published
2025-05-19
DOI
https://doi.org/10.1016/j.rechem.2025.102370
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tricaprylylmethylammonium chloride-enhanced high sensitivity potentiometric sensor for iodide assessment in antiseptic solutions

Niaf A. Badahdah, Nora O. Saleem, Muneer E Alzuhiri, Ayman A. Gouda et al.
Results in Chemistry
Analytical Chemistry and Sensors
article

Tricaprylylmethylammonium chloride-enhanced high sensitivity potentiometric sensor for iodide assessment in antiseptic solutions

Niaf A. Badahdah, Nora O. Saleem, Muneer E Alzuhiri, Ayman A. Gouda, Mоhsеn M. Zаrеh, A. Mohamed, Ali H. Magrabi, Asim L. Jilani
article en

Abstract

A high-sensitivity potentiometric iodide sensor was fabricated using tricaprylylmethylammonium chloride (TCMACl) as an ion exchanger incorporated into a PVC matrix. The constructed electrode demonstrated high performance characteristics toward I − ion, with a Nernstian slope of −59.2 ± 0.17 mV/decade, a wide dynamic working range extending from 5 × 10 −7 to 5 × 10 −2 M, and a low detection limit of 5.0 × 10 −7 M. The proposed electrode was characterized by its fast response time of 4 s toward the analyte during calibration and the evaluation of iodide in samples. The surface of the prepared membrane was examined using SEM-EDX analysis, supported by mapping, and the stability of TCMACl in the membrane was studied using a mass loss method. The responsive sensor successfully determined the iodide concentration in antiseptic pharmaceutical drugs, achieving an average recovery of 96 % with a relative standard deviation (RSD) of 1.81 %. Additionally, the constructed sensor was applied as an indicator electrode in the potentiometric titration of AgNO 3 against KI solution. • A high-sensitivity iodide sensor was successfully developed using tricaprylylmethyl ammonium chloride as ion-exchanger. • Mapping demonstrated the iodide distribution on the electrode surface. • The iodide sensor revealed a faster response time of 4 s than other previously reported, highlighting its potential for real-time monitoring applications. • The developed sensor successfully determined the iodide concentration in antiseptic pharmaceutical drugs and was applied as an indicator electrode in the potentiometric titration of AgNO₃ against KI solution.

Results in ChemistryVol. 16
Zagazig University (EG), Ministry of Health (SA)
Department of Chemistry, University of York, Faculty of Science, Zagazig University
Affordable and clean energy
Openalex Percentile: Top 86%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.