A Reconstruction of Boiling Point Elevation Apparatus

The aim of this study is identifying how to solve students' misconceptions on the topic of (H2S) problem by conducting boiling point elevation experiments. This research was conducted into two steps. Firstly, proved the construction error of the boiling point in LabMaya. Secondly, is the to overcome it. In the first step, a real experiment was conducted based on the simulation in LabMaya. In the second step using the reconstructed set of tools. Results of the data analysis showed that the LabMaya construction proved to cause a very large reduction in solvent. The errors were 27.63%, 33.33%, and 40.75%, respectively. The reconstructed device proved to be able to maintain the amount of solvent so that it would not change the concentration of the solution. This equipment has a very small error, less than 5%. Of the three condensers used, namely Vigreux, Liebig, and Graham, it was found that the Graham condenser had the best accuracy

Authors

Institutions

Publication Details

Journal
Jurnal Penelitian Pendidikan IPA
Published
2025-04-25
DOI
https://doi.org/10.29303/jppipa.v11i4.9070
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Reconstruction of Boiling Point Elevation Apparatus

Liliasari Liliasari, Ijang Rohman, Nurhamida Anar, Triannisa Rahmawati
Jurnal Penelitian Pendidikan IPA
Engineering Applied Research
article

A Reconstruction of Boiling Point Elevation Apparatus

Liliasari Liliasari, Ijang Rohman, Nurhamida Anar, Triannisa Rahmawati
article en

Abstract

The aim of this study is identifying how to solve students' misconceptions on the topic of (H2S) problem by conducting boiling point elevation experiments. This research was conducted into two steps. Firstly, proved the construction error of the boiling point in LabMaya. Secondly, is the to overcome it. In the first step, a real experiment was conducted based on the simulation in LabMaya. In the second step using the reconstructed set of tools. Results of the data analysis showed that the LabMaya construction proved to cause a very large reduction in solvent. The errors were 27.63%, 33.33%, and 40.75%, respectively. The reconstructed device proved to be able to maintain the amount of solvent so that it would not change the concentration of the solution. This equipment has a very small error, less than 5%. Of the three condensers used, namely Vigreux, Liebig, and Graham, it was found that the Graham condenser had the best accuracy

Jurnal Penelitian Pendidikan IPAVol. 11(4)
Indonesia University of Education (ID)
Universitas Pendidikan Indonesia
Openalex Percentile: Top 89%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.