The Loading Capacity of RC Column Member with Termination Point of Main Reinforcement Affected by ASR

The main reinforcement ratio of piers constructed before 1980, when the standards older than the 1980 specifications for road bridges were applied, is often around 1.0%, and at termination point of main reinforcement is less than 1/2, the main reinforcement ratio is less than 0.5%. In such piers, cracks due to ASR expansion are more likely to occur, and the effect on loading capacity is a concern. In this study, to clarify the seismic performance of piers with ASR deterioration, RC column specimens with ASR deterioration and non- deteriorated RC column specimens for comparison were fabricated to simulate the piers at that time, and the progress observation and loading tests were conducted on one non- deteriorated RC column specimen and two RC column specimens with ASR deterioration. The loading test results showed that the maximum load of the specimen with ASR deterioration increased due to chemical prestress compared to the specimen without ASR deterioration. However, the specimen with ASR deterioration decreased toughness compared with the specimen.

Authors

Institutions

Publication Details

Journal
Journal of the Society of Materials Science Japan
Published
2025-05-15
DOI
https://doi.org/10.2472/jsms.74.336
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Loading Capacity of RC Column Member with Termination Point of Main Reinforcement Affected by ASR

Susumu INOUE, Yasuhiro Mikata, Yuto Hayata, Jun Taniguchi
Journal of the Society of Materials Science Japan
Structural Behavior of Reinforced Concrete
article

The Loading Capacity of RC Column Member with Termination Point of Main Reinforcement Affected by ASR

Susumu INOUE, Yasuhiro Mikata, Yuto Hayata, Jun Taniguchi
article en

Abstract

The main reinforcement ratio of piers constructed before 1980, when the standards older than the 1980 specifications for road bridges were applied, is often around 1.0%, and at termination point of main reinforcement is less than 1/2, the main reinforcement ratio is less than 0.5%. In such piers, cracks due to ASR expansion are more likely to occur, and the effect on loading capacity is a concern. In this study, to clarify the seismic performance of piers with ASR deterioration, RC column specimens with ASR deterioration and non- deteriorated RC column specimens for comparison were fabricated to simulate the piers at that time, and the progress observation and loading tests were conducted on one non- deteriorated RC column specimen and two RC column specimens with ASR deterioration. The loading test results showed that the maximum load of the specimen with ASR deterioration increased due to chemical prestress compared to the specimen without ASR deterioration. However, the specimen with ASR deterioration decreased toughness compared with the specimen.

Journal of the Society of Materials Science JapanVol. 74(5)
Osaka Institute of Technology (JP)
Openalex Percentile: Top 89%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.