A Co(II)-Organic Coordination Polymer and Its Hydroxyl Multiwalled Carbon Nanotube Composite Incorporating 2-Iodo-4-sulfobenzoate Exhibiting Dual Electrochemical Sensing Performance for NO<sub>2</sub><sup>–</sup> and Fe<sup>3+</sup>

The novel Co(II) coordination polymer incorporating 2-iodo-4-sulfobenzoic acid (H<sub>2</sub>isba) and a pliable 1,4-bis(benzimidazole-1-methyl) benzene (bdbmb) ligand, {[Co(bdbmb)(H<sub>2</sub>O)<sub>4</sub>]·isba·2H<sub>2</sub>O·2DMA}<sub>n</sub> (Co(II)-CP), was synthesized. In addition, the composite of Co(II)-CP with the short hydroxyl multiwalled carbon nanotubes (Co(II)-CP@HCNTs) was prepared via an <i>in situ</i> preparation strategy. Amperometric current response reveals that the glass carbon electrodes (GCEs) of Co(II)-CP and Co(II)-CP@HCNTs exhibit highly sensitive electrochemical sensing toward NO<sub>2</sub><sup>-</sup> and Fe<sup>3+</sup> in the corresponding electrolytes. Co(II)-CP@HCNTs demonstrate superior electrocatalytic performance toward NO<sub>2</sub><sup>-</sup> oxidation and Fe<sup>3+</sup>reduction to Co(II)-CP. The sensing mechanisms for NO<sub>2</sub><sup>-</sup> and Fe<sup>3+</sup> were illustrated with Hirshfeld surface analysis and density of states calculations. Furthermore, this methodology was successfully implemented on a miniaturized screen-printed electrode (SPE) platform. Among the three tested electrodes, the Co(II)-CP@HCNT-modified SPEs exhibited superior sensing capabilities, showing response ranges of 0.002-20 mM for nitrite and 0.002-38 mM for ferric ions, respectively. The calculated detection limits reached 0.12 μM for NO<sub>2</sub><sup>-</sup> (δ = 0.00396 μA, <i>N</i> = 10) and 0.30 μM for Fe<sup>3+</sup> (δ = 0.00201 μA, <i>N</i> = 10). Moreover, Co(II)-CP@HCNTs/SPE was further validated through practical applications for the detection of both analytes in real-world samples in the respective electrolytes.

Authors

Institutions

Publication Details

Journal
Inorganic Chemistry
Published
2025-05-19
DOI
https://doi.org/10.1021/acs.inorgchem.5c00484
Citations
8
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
4.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Co(II)-Organic Coordination Polymer and Its Hydroxyl Multiwalled Carbon Nanotube Composite Incorporating 2-Iodo-4-sulfobenzoate Exhibiting Dual Electrochemical Sensing Performance for NO2– and Fe3+

Ting Guo, Kou‐Lin Zhang, Qi Wang, Jia Chen et al.
8 citations
Inorganic Chemistry
Conducting polymers and applications
4.85
article

A Co(II)-Organic Coordination Polymer and Its Hydroxyl Multiwalled Carbon Nanotube Composite Incorporating 2-Iodo-4-sulfobenzoate Exhibiting Dual Electrochemical Sensing Performance for NO2– and Fe3+

Ting Guo, Kou‐Lin Zhang, Qi Wang, Jia Chen, Yuan‐Wen Yang
article en
8 citations

Abstract

The novel Co(II) coordination polymer incorporating 2-iodo-4-sulfobenzoic acid (H<sub>2</sub>isba) and a pliable 1,4-bis(benzimidazole-1-methyl) benzene (bdbmb) ligand, {[Co(bdbmb)(H<sub>2</sub>O)<sub>4</sub>]·isba·2H<sub>2</sub>O·2DMA}<sub>n</sub> (Co(II)-CP), was synthesized. In addition, the composite of Co(II)-CP with the short hydroxyl multiwalled carbon nanotubes (Co(II)-CP@HCNTs) was prepared via an <i>in situ</i> preparation strategy. Amperometric current response reveals that the glass carbon electrodes (GCEs) of Co(II)-CP and Co(II)-CP@HCNTs exhibit highly sensitive electrochemical sensing toward NO<sub>2</sub><sup>-</sup> and Fe<sup>3+</sup> in the corresponding electrolytes. Co(II)-CP@HCNTs demonstrate superior electrocatalytic performance toward NO<sub>2</sub><sup>-</sup> oxidation and Fe<sup>3+</sup>reduction to Co(II)-CP. The sensing mechanisms for NO<sub>2</sub><sup>-</sup> and Fe<sup>3+</sup> were illustrated with Hirshfeld surface analysis and density of states calculations. Furthermore, this methodology was successfully implemented on a miniaturized screen-printed electrode (SPE) platform. Among the three tested electrodes, the Co(II)-CP@HCNT-modified SPEs exhibited superior sensing capabilities, showing response ranges of 0.002-20 mM for nitrite and 0.002-38 mM for ferric ions, respectively. The calculated detection limits reached 0.12 μM for NO<sub>2</sub><sup>-</sup> (δ = 0.00396 μA, <i>N</i> = 10) and 0.30 μM for Fe<sup>3+</sup> (δ = 0.00201 μA, <i>N</i> = 10). Moreover, Co(II)-CP@HCNTs/SPE was further validated through practical applications for the detection of both analytes in real-world samples in the respective electrolytes.

Inorganic ChemistryVol. 64(21)
Yangzhou University (CN)
Natural Science Foundation of Jiangsu Province
Openalex Percentile: Top 5%
Conducting polymers and applications
4.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.