Performance analysis of the impact of sloped absorber dimensions on the performance of solar chimney power plants

Abstract Several geometric parameters have been investigated in solar chimney power with the aim of determining the optimal geometric parameters and enhancing power generation. The aim of this study is to determine the optimal dimensions of the sloped absorber surface and analyze its impact on the power output of the system at the Manzanares plant. The sloped absorber surface studied includes a singular triangular shape where the effect of the central high and absorber slope radius is studied. To conduct this study, A Computational Fluid Dynamics CFD model developed using COMSOL Multiphysics with the k – ε turbulence model was employed. The outcomes of this study demonstrate that the maximum air velocity in the reference Manzanares design, initially measured at 15 m s −1 , increases by 26% with the optimized sloped absorber configuration. Specifically, at a central height of 1.10 m and an absorber slope radius of 122 m, the maximum velocity reaches 18.9 m s −1 . Furthermore, the power output rises by 34%, reaching 67 kW compared to the reference case of 50 kW.

Authors

Institutions

Publication Details

Journal
Journal of Thermal Analysis and Calorimetry
Published
2025-05-19
DOI
https://doi.org/10.1007/s10973-025-14307-4
Citations
2
Primary Topic
Solar Energy Systems and Technologies
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance analysis of the impact of sloped absorber dimensions on the performance of solar chimney power plants

Toufik Tahri, Erdem Cüce, Youcef Benettayeb, Abderrahmen Benbouali
2 citations
Journal of Thermal Analysis and Calorimetry
Solar Energy Systems and Technologies
1.43
article

Performance analysis of the impact of sloped absorber dimensions on the performance of solar chimney power plants

Toufik Tahri, Erdem Cüce, Youcef Benettayeb, Abderrahmen Benbouali
article en
2 citations

Abstract

Abstract Several geometric parameters have been investigated in solar chimney power with the aim of determining the optimal geometric parameters and enhancing power generation. The aim of this study is to determine the optimal dimensions of the sloped absorber surface and analyze its impact on the power output of the system at the Manzanares plant. The sloped absorber surface studied includes a singular triangular shape where the effect of the central high and absorber slope radius is studied. To conduct this study, A Computational Fluid Dynamics CFD model developed using COMSOL Multiphysics with the k – ε turbulence model was employed. The outcomes of this study demonstrate that the maximum air velocity in the reference Manzanares design, initially measured at 15 m s −1 , increases by 26% with the optimized sloped absorber configuration. Specifically, at a central height of 1.10 m and an absorber slope radius of 122 m, the maximum velocity reaches 18.9 m s −1 . Furthermore, the power output rises by 34%, reaching 67 kW compared to the reference case of 50 kW.

Journal of Thermal Analysis and CalorimetryVol. 150(12)
Chandigarh University (IN), Recep Tayyip Erdoğan University (TR), Hassiba Benbouali University of Chlef (DZ), Chitkara University (IN)
Affordable and clean energy
Openalex Percentile: Top 20%
Solar Energy Systems and Technologies
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.