Photovoltaic System Performance Under Partial Shading Conditions: Insight into the Roles of Bypass Diode Numbers and Inverter Efficiency Curve

Partial shading is a common challenge influencing the performance of photovoltaic (PV) systems, particularly in urban and residential applications. A practical solution to mitigate hotspot formation due to shading is the use of bypass diodes. Increasing the number of bypass diodes further enhances PV system performance but alters the global maximum power points (MPPs), shifting their voltage locations and power magnitudes, consequently resulting in a change in the operating points in the efficiency curve of the inverters. This study investigates the impact of bypass diode numbers and inverter efficiency curves on PV system performance under various partial shading conditions. The analysis systematically deals with three inverters with different efficiency characteristics in terms of loading and input voltage, as well as module configurations with different numbers of bypass diodes. Additionally, three more factors—ambient temperature, inverter loading ratio by varying the number of series-connected PV modules, and shading intensity—are considered in the context of bypass diodes and inverter characteristics through the efficiency curve. The global MPPs of PV modules under different cases are simulated using a Simscape/Simulink-based circuit model with random irradiance samples. The results indicate the formation of bands according to the voltage that vary with bypass diode configurations. In this manner, utilizing the probabilities of these bands and inverter efficiency curves, the average PV system performance is determined for each case. The findings reveal the effects of the relationship between bypass diode configurations and inverter efficiency on PV system performance. As partial shading is especially common in dense urban areas, the results are of interest for the development of resilient and sustainable PV installations.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-05-18
DOI
https://doi.org/10.3390/su17104626
Citations
6
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
2.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Photovoltaic System Performance Under Partial Shading Conditions: Insight into the Roles of Bypass Diode Numbers and Inverter Efficiency Curve

Hatice Gül Sezgin-Ugranlı
6 citations
Sustainability
Photovoltaic System Optimization Techniques
2.18
article

Photovoltaic System Performance Under Partial Shading Conditions: Insight into the Roles of Bypass Diode Numbers and Inverter Efficiency Curve

Hatice Gül Sezgin-Ugranlı
article en
6 citations

Abstract

Partial shading is a common challenge influencing the performance of photovoltaic (PV) systems, particularly in urban and residential applications. A practical solution to mitigate hotspot formation due to shading is the use of bypass diodes. Increasing the number of bypass diodes further enhances PV system performance but alters the global maximum power points (MPPs), shifting their voltage locations and power magnitudes, consequently resulting in a change in the operating points in the efficiency curve of the inverters. This study investigates the impact of bypass diode numbers and inverter efficiency curves on PV system performance under various partial shading conditions. The analysis systematically deals with three inverters with different efficiency characteristics in terms of loading and input voltage, as well as module configurations with different numbers of bypass diodes. Additionally, three more factors—ambient temperature, inverter loading ratio by varying the number of series-connected PV modules, and shading intensity—are considered in the context of bypass diodes and inverter characteristics through the efficiency curve. The global MPPs of PV modules under different cases are simulated using a Simscape/Simulink-based circuit model with random irradiance samples. The results indicate the formation of bands according to the voltage that vary with bypass diode configurations. In this manner, utilizing the probabilities of these bands and inverter efficiency curves, the average PV system performance is determined for each case. The findings reveal the effects of the relationship between bypass diode configurations and inverter efficiency on PV system performance. As partial shading is especially common in dense urban areas, the results are of interest for the development of resilient and sustainable PV installations.

SustainabilityVol. 17(10)
Izmir University (TR), Bakırçay Üniversitesi
Openalex Percentile: Top 12%
Photovoltaic System Optimization Techniques
2.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.