Numerical Investigation of Gas Exchange Processes in Hollow-Fiber Membrane Bundles

The geometric configuration of fiber bundles plays a critical role in gas transfer for membrane oxygenators; however, experimentally studying its impact on gas transfer distribution is challenging. This study numerically examines oxygen and carbon dioxide transfer processes in a mini-oxygenator with a fiber bundle, focusing on the effects of inlet blood flow rate, fiber bundle cross-sectional area, fiber spacing, and wall effects. The numerical model, validated against existing data, was used to analyze blood gas parameter distribution under varying conditions. The findings indicate that an increase in blood inlet flow rate delays oxygen saturation and reduces the partial pressure of oxygen at the same location within the fiber bundle. Furthermore, the cross-sectional area perpendicular to the inlet flow direction, when maintaining a consistent fiber bundle volume, noticeably impacts gas exchange performance. Fiber spacing strongly affects carbon dioxide-related parameters but has negligible impact on oxygen-related parameters. The wall effect on gas transfer is limited to the outermost fiber layer adjacent to the wall. These studies elucidate the relationship between gas transfer performance and geometric factors, thereby providing insights for optimizing fiber bundle geometry in the design of membrane oxygenators to enhance efficiency and effectiveness.

Authors

Institutions

Publication Details

Journal
ASAIO Journal
Published
2025-05-19
DOI
https://doi.org/10.1097/mat.0000000000002444
Citations
2
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
1.46
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Investigation of Gas Exchange Processes in Hollow-Fiber Membrane Bundles

Wei Li
2 citations
ASAIO Journal
Fuel Cells and Related Materials
1.46
article

Numerical Investigation of Gas Exchange Processes in Hollow-Fiber Membrane Bundles

Wei Li
article en
2 citations

Abstract

The geometric configuration of fiber bundles plays a critical role in gas transfer for membrane oxygenators; however, experimentally studying its impact on gas transfer distribution is challenging. This study numerically examines oxygen and carbon dioxide transfer processes in a mini-oxygenator with a fiber bundle, focusing on the effects of inlet blood flow rate, fiber bundle cross-sectional area, fiber spacing, and wall effects. The numerical model, validated against existing data, was used to analyze blood gas parameter distribution under varying conditions. The findings indicate that an increase in blood inlet flow rate delays oxygen saturation and reduces the partial pressure of oxygen at the same location within the fiber bundle. Furthermore, the cross-sectional area perpendicular to the inlet flow direction, when maintaining a consistent fiber bundle volume, noticeably impacts gas exchange performance. Fiber spacing strongly affects carbon dioxide-related parameters but has negligible impact on oxygen-related parameters. The wall effect on gas transfer is limited to the outermost fiber layer adjacent to the wall. These studies elucidate the relationship between gas transfer performance and geometric factors, thereby providing insights for optimizing fiber bundle geometry in the design of membrane oxygenators to enhance efficiency and effectiveness.

ASAIO JournalVol. 72(1)
MicroPort (China) (CN)
Openalex Percentile: Top 17%
Fuel Cells and Related Materials
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.