Quantifying Intra- and Inter-Observer Variabilities in Manual Contours for Radiotherapy: Evaluation of an MR Tumor Autocontouring Algorithm for Liver, Prostate, and Lung Cancer Patients

Real-time tumor-tracked radiotherapy with a linear accelerator-magnetic resonance (linac-MR) hybrid system requires accurate tumor delineation at a fast MR imaging rate. Various autocontouring methods have been previously evaluated against “gold standard” manual contours by experts. However, manually drawn contours have inherent intra- and inter-observer variations. We aim to quantify these variations and evaluate our tumor-autocontouring algorithm against the manual contours. Ten liver, ten prostate, and ten lung cancer patients were scanned using a 3 tesla (T) magnetic resonance imaging (MRI) scanner with a 2D balanced steady-state free precession (bSSFP) sequence at 4 frames/s. Three experts manually contoured the tumor in two sessions. For autocontouring, an in-house built U-Net-based autocontouring algorithm was used, whose hyperparameters were optimized for each patient, expert, and session (PES). For evaluation, (A) Automatic vs. Manual and (B) Manual vs. Manual contour comparisons were performed. For (A) and (B), three types of comparisons were performed: (a) same expert same session, (b) same expert different session, and (c) different experts, using Dice coefficient (DC), centroid displacement (CD), and the Hausdorff distance (HD). For (A), the algorithm was trained using one expert’s contours and its autocontours were compared to contours from (a)–(c). For Automatic vs. Manual evaluations (Aa–Ac), DC = 0.91, 0.86, 0.78, CD = 1.3, 1.8, 2.7 mm, and HD = 3.1, 4.6, 7.0 mm averaged over 30 patients were achieved, respectively. For Manual vs. Manual evaluations (Ba–Bc), DC = 1.00, 0.85, 0.77, CD = 0.0, 2.1, 2.8 mm, and HD = 0.0, 4.9, 7.2 mm were achieved, respectively. We have quantified the intra- and inter-observer variations in manual contouring of liver, prostate, and lung patients. Our PES-specific optimized algorithm generated autocontours with agreement levels comparable to these manual variations, but with high efficiency (54 ms/autocontour vs. 9 s/manual contour).

Authors

Institutions

Publication Details

Journal
Algorithms
Published
2025-05-19
DOI
https://doi.org/10.3390/a18050290
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying Intra- and Inter-Observer Variabilities in Manual Contours for Radiotherapy: Evaluation of an MR Tumor Autocontouring Algorithm for Liver, Prostate, and Lung Cancer Patients

Asmara Waheed, Nawaid Usmani, Arun Elangovan, Gawon Han et al.
1 links
Algorithms
Advanced Radiotherapy Techniques
article

Quantifying Intra- and Inter-Observer Variabilities in Manual Contours for Radiotherapy: Evaluation of an MR Tumor Autocontouring Algorithm for Liver, Prostate, and Lung Cancer Patients

Asmara Waheed, Nawaid Usmani, Arun Elangovan, Gawon Han, Jordan Wong, Jihyun Yun, Keith Wachowicz, Zsolt Gabos, B. G. Fallone
article en

Abstract

Real-time tumor-tracked radiotherapy with a linear accelerator-magnetic resonance (linac-MR) hybrid system requires accurate tumor delineation at a fast MR imaging rate. Various autocontouring methods have been previously evaluated against “gold standard” manual contours by experts. However, manually drawn contours have inherent intra- and inter-observer variations. We aim to quantify these variations and evaluate our tumor-autocontouring algorithm against the manual contours. Ten liver, ten prostate, and ten lung cancer patients were scanned using a 3 tesla (T) magnetic resonance imaging (MRI) scanner with a 2D balanced steady-state free precession (bSSFP) sequence at 4 frames/s. Three experts manually contoured the tumor in two sessions. For autocontouring, an in-house built U-Net-based autocontouring algorithm was used, whose hyperparameters were optimized for each patient, expert, and session (PES). For evaluation, (A) Automatic vs. Manual and (B) Manual vs. Manual contour comparisons were performed. For (A) and (B), three types of comparisons were performed: (a) same expert same session, (b) same expert different session, and (c) different experts, using Dice coefficient (DC), centroid displacement (CD), and the Hausdorff distance (HD). For (A), the algorithm was trained using one expert’s contours and its autocontours were compared to contours from (a)–(c). For Automatic vs. Manual evaluations (Aa–Ac), DC = 0.91, 0.86, 0.78, CD = 1.3, 1.8, 2.7 mm, and HD = 3.1, 4.6, 7.0 mm averaged over 30 patients were achieved, respectively. For Manual vs. Manual evaluations (Ba–Bc), DC = 1.00, 0.85, 0.77, CD = 0.0, 2.1, 2.8 mm, and HD = 0.0, 4.9, 7.2 mm were achieved, respectively. We have quantified the intra- and inter-observer variations in manual contouring of liver, prostate, and lung patients. Our PES-specific optimized algorithm generated autocontours with agreement levels comparable to these manual variations, but with high efficiency (54 ms/autocontour vs. 9 s/manual contour).

AlgorithmsVol. 18(5)
University of Alberta (CA), University of Calgary (CA)
Canadian Institutes of Health Research
Openalex Percentile: Top 87%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.