A wearable belt for non-invasive monitoring of heart failure parameters

Heart failure is a fatal cardiovascular disease in which the heart is unable to pump sufficient blood to meet the requirements of the body. Traditionally, implantable cardioverter defibrillator (ICD) is used for the monitoring and management of heart failure. However, ICD is an implantable solution that requires surgery and is expensive as well. We have previously developed a wearable device that monitors parameters similar to ICD for the monitoring and management of heart failure. These parameters include heart rate, thoracic impedance and activity status. This paper, we will discuss the experimentation and results of the device on heart failure patients. We use the device to measure heart rate, thoracic impedance, and activity status on heart failure patients with ICDs. The results obtained from our non-invasive device are then compared with those obtained from the ICDs to validate our device. Our non-invasive device is shown to perform close to the ICDs rendering it a cost-effective alternative for heart failure patients. • A wearable belt for the parameters of heart failure patients. • Comparative analysis of the developed non-invasive solution with the traditional implantable solutions. • Study based on actual heart failure patients with reduced ejection fraction with Implantable Cardioverter Defibrillators (ICD) implanted.

Authors

Institutions

Publication Details

Journal
Sensing and Bio-Sensing Research
Published
2025-05-18
DOI
https://doi.org/10.1016/j.sbsr.2025.100804
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A wearable belt for non-invasive monitoring of heart failure parameters

Mary Ann Leavitt, Imad Mahgoub, Waseem Asghar, Sheikh Muhammad Asher Iqbal
1 citations
Sensing and Bio-Sensing Research
Non-Invasive Vital Sign Monitoring
0.67
article

A wearable belt for non-invasive monitoring of heart failure parameters

Mary Ann Leavitt, Imad Mahgoub, Waseem Asghar, Sheikh Muhammad Asher Iqbal
article en
1 citations

Abstract

Heart failure is a fatal cardiovascular disease in which the heart is unable to pump sufficient blood to meet the requirements of the body. Traditionally, implantable cardioverter defibrillator (ICD) is used for the monitoring and management of heart failure. However, ICD is an implantable solution that requires surgery and is expensive as well. We have previously developed a wearable device that monitors parameters similar to ICD for the monitoring and management of heart failure. These parameters include heart rate, thoracic impedance and activity status. This paper, we will discuss the experimentation and results of the device on heart failure patients. We use the device to measure heart rate, thoracic impedance, and activity status on heart failure patients with ICDs. The results obtained from our non-invasive device are then compared with those obtained from the ICDs to validate our device. Our non-invasive device is shown to perform close to the ICDs rendering it a cost-effective alternative for heart failure patients. • A wearable belt for the parameters of heart failure patients. • Comparative analysis of the developed non-invasive solution with the traditional implantable solutions. • Study based on actual heart failure patients with reduced ejection fraction with Implantable Cardioverter Defibrillators (ICD) implanted.

Sensing and Bio-Sensing ResearchVol. 48
Florida Atlantic University (US)
Openalex Percentile: Top 32%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A wearable belt for non-invasive monitoring of heart failure parameters — Mary Ann Leavitt, Imad Mahgoub, et al. · Sensing and Bio-Sensing Research (2025) | TGRS Research Map | TGRS