The Effect of EDTA Blood Sample Stability on Hemoglobin and Hematocrit Examination in Kedung II Public Health Center Employees Using an Automatic Method

This study aims to determine the effect of EDTA blood sample stability on hemoglobin (Hb) and hematocrit (Ht) examination results using an automatic method. EDTA blood samples from 38 employees of Kedung II Public Health Center were examined immediately (0 hours), after a 1-hour delay at room temperature (17–210C), and after a 1-hour delay in a refrigerator (2–80C). The results were analyzed using a Two-Way ANOVA test. The study showed no significant differences in hemoglobin and hematocrit levels between the three storage conditions (ρ 0.05). The average hemoglobin levels were 12.834 g/dL at 0 hours, 12.797 g/dL after 1 hour at room temperature, and 12.829 g/dL after 1 hour in the refrigerator. The average hematocrit levels were 38.484% at 0 hours, 38.321% after 1 hour at room temperature, and 38.434% after 1 hour in the refrigerator. The conclusion of this study is that storing EDTA blood samples for 1 hour, whether at room temperature or in the refrigerator, does not significantly affect hemoglobin and hematocrit examination results.

Authors

Publication Details

Journal
Jaringan Laboratorium Medis
Published
2025-05-19
DOI
https://doi.org/10.31983/jlm.v7i1.12872
Primary Topic
Digital Imaging for Blood Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of EDTA Blood Sample Stability on Hemoglobin and Hematocrit Examination in Kedung II Public Health Center Employees Using an Automatic Method

Arief Adi Saputro, Yunita Rusidah, Anisa Ayu Anjani, Dewi Hartinah et al.
Jaringan Laboratorium Medis
Digital Imaging for Blood Diseases
article

The Effect of EDTA Blood Sample Stability on Hemoglobin and Hematocrit Examination in Kedung II Public Health Center Employees Using an Automatic Method

Arief Adi Saputro, Yunita Rusidah, Anisa Ayu Anjani, Dewi Hartinah, Shinta Dwi Kurnia
article en

Abstract

This study aims to determine the effect of EDTA blood sample stability on hemoglobin (Hb) and hematocrit (Ht) examination results using an automatic method. EDTA blood samples from 38 employees of Kedung II Public Health Center were examined immediately (0 hours), after a 1-hour delay at room temperature (17–210C), and after a 1-hour delay in a refrigerator (2–80C). The results were analyzed using a Two-Way ANOVA test. The study showed no significant differences in hemoglobin and hematocrit levels between the three storage conditions (ρ 0.05). The average hemoglobin levels were 12.834 g/dL at 0 hours, 12.797 g/dL after 1 hour at room temperature, and 12.829 g/dL after 1 hour in the refrigerator. The average hematocrit levels were 38.484% at 0 hours, 38.321% after 1 hour at room temperature, and 38.434% after 1 hour in the refrigerator. The conclusion of this study is that storing EDTA blood samples for 1 hour, whether at room temperature or in the refrigerator, does not significantly affect hemoglobin and hematocrit examination results.

Jaringan Laboratorium MedisVol. 7(1)
Openalex Percentile: Top 91%
Digital Imaging for Blood Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.