Optimization of variables for cadmium and copper removal using magnetic nanocomposite

This study aims to investigate cadmium and copper ultrasound-assisted removal efficiency on a laboratory scale using a cobalt ferrite/activated carbon (COF/AC) composite as an adsorbent. For this purpose, the effect of four independent variables (i.e., composite amount, pH, heavy metal concentrations, and ultrasound radiation time) on the performance of the cadmium and copper removal was investigated. The COF/AC composite was characterized using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), Brunauer-Emmett-Teller (BET), X-ray diffraction (XRD), and vibrating-sample magnetometer (VSM). The SEM and XRD techniques showed the successful synthesis of the COF/AC composite. The COF/AC composite has a surface area of 659.4 m<sup>2</sup> g<sup>-1</sup>, an average diameter of 3.6 nm, and a pore volume of 0.482 cm<sup>3</sup> g<sup>-1</sup>. In this study, R<sup>2</sup> ˃ 0.99 and Adj-R<sup>2</sup> ˃ 0.98 for both analytes signify a high agreement between the obtained laboratory data and the model-predicted data. The analysis results for heavy metal removal revealed the following optimal conditions: the composite content of 0.22 g, ultrasound radiation time of 22 min, concentration of 19 mg L<sup>-1</sup>, and pH of 5. Under optimal conditions, the maximum removal efficiency reached 93.46% and 97.45% for cadmium and copper, respectively. The COF/AC composite reuse results showed no significant decrease in removal efficiency up to 4 times of use during the adsorption and desorption process. Analysis of real samples showed that the removal rates of cadmium and copper were 89.62% and 96.37%, respectively.

Authors

Institutions

Publication Details

Journal
BMC Chemistry
Published
2025-05-18
DOI
https://doi.org/10.1186/s13065-025-01502-5
Citations
1
Primary Topic
Adsorption and biosorption for pollutant removal
Type
article
Field-Weighted Citation Impact
0.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of variables for cadmium and copper removal using magnetic nanocomposite

Alzahraa S. Abdulwahid, Mohammed Ahmed Mustafa, Laith H. Alzubaidi, Amjed Qasim Mohammed et al.
1 citations
BMC Chemistry
Adsorption and biosorption for pollutant removal
0.82
article

Optimization of variables for cadmium and copper removal using magnetic nanocomposite

Alzahraa S. Abdulwahid, Mohammed Ahmed Mustafa, Laith H. Alzubaidi, Amjed Qasim Mohammed, Ali Kazemi, Chou‐Yi Hsu, Amina Hussein, Usama Kadem Radi, Ahmed Ali Ami, Ghadir Kamil Ghadir, Harpreet Kaur, Pooja Bansal, Sahira Qasim Namaha
article en
1 citations

Abstract

This study aims to investigate cadmium and copper ultrasound-assisted removal efficiency on a laboratory scale using a cobalt ferrite/activated carbon (COF/AC) composite as an adsorbent. For this purpose, the effect of four independent variables (i.e., composite amount, pH, heavy metal concentrations, and ultrasound radiation time) on the performance of the cadmium and copper removal was investigated. The COF/AC composite was characterized using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), Brunauer-Emmett-Teller (BET), X-ray diffraction (XRD), and vibrating-sample magnetometer (VSM). The SEM and XRD techniques showed the successful synthesis of the COF/AC composite. The COF/AC composite has a surface area of 659.4 m<sup>2</sup> g<sup>-1</sup>, an average diameter of 3.6 nm, and a pore volume of 0.482 cm<sup>3</sup> g<sup>-1</sup>. In this study, R<sup>2</sup> ˃ 0.99 and Adj-R<sup>2</sup> ˃ 0.98 for both analytes signify a high agreement between the obtained laboratory data and the model-predicted data. The analysis results for heavy metal removal revealed the following optimal conditions: the composite content of 0.22 g, ultrasound radiation time of 22 min, concentration of 19 mg L<sup>-1</sup>, and pH of 5. Under optimal conditions, the maximum removal efficiency reached 93.46% and 97.45% for cadmium and copper, respectively. The COF/AC composite reuse results showed no significant decrease in removal efficiency up to 4 times of use during the adsorption and desorption process. Analysis of real samples showed that the removal rates of cadmium and copper were 89.62% and 96.37%, respectively.

BMC ChemistryVol. 19(1)
Jain University (IN), Mustansiriyah University (IQ), University of Babylon (IQ), Shobhit University (IN), Thi Qar University (IQ), Alrafidain University College (IQ), Al-Turath University (IQ), Iraqi University (IQ), Al Mansour University College (IQ), University of Misan (IQ), Al-Nisour University College (IQ), Vivekananda Global University (IN), University of Samarra (IQ), Al-Hadi University College, Chia Nan University of Pharmacy and Science (TW)
Tehran University of Medical Sciences and Health Services
Clean water and sanitation
Openalex Percentile: Top 26%
Adsorption and biosorption for pollutant removal
0.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.