EFFECT OF PHOTON ENERGY ON THE RADIATION SENSITIVITY OF HEMA POLYMER GEL DOSIMETER BASED ON NEAR INFRARED EVALUATION

This study investigates the photon energy dependence of HEMA polymer gel dosimeters (PGDs) with maltose additive, evaluated using near-infrared (IR) spectrophotometry. Two batches of PGDs with varying maltose concentrations (0–520 mM) were irradiated using 6 MV and 10 MV photon beams. Absorbance-dose response curves were plotted, and sensitivities were compared using regression analysis and ANOVA. Results indicated a significant difference in sensitivity between the two photon energies (p < 0.05), suggesting photon energy dependence in the evaluated HEMA PGDs. These findings emphasize the need for energy-specific calibration when using HEMA PGDs in clinical applications.

Authors

Institutions

Publication Details

Journal
FUDMA Journal of Sciences
Published
2025-05-04
DOI
https://doi.org/10.33003/fjs-2025-09(ahbsi)-3531
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EFFECT OF PHOTON ENERGY ON THE RADIATION SENSITIVITY OF HEMA POLYMER GEL DOSIMETER BASED ON NEAR INFRARED EVALUATION

M. Alhassan, Emmanuel Joseph, Abdulrahman Zuru Namadi
FUDMA Journal of Sciences
Advanced Radiotherapy Techniques
article

EFFECT OF PHOTON ENERGY ON THE RADIATION SENSITIVITY OF HEMA POLYMER GEL DOSIMETER BASED ON NEAR INFRARED EVALUATION

M. Alhassan, Emmanuel Joseph, Abdulrahman Zuru Namadi
article en

Abstract

This study investigates the photon energy dependence of HEMA polymer gel dosimeters (PGDs) with maltose additive, evaluated using near-infrared (IR) spectrophotometry. Two batches of PGDs with varying maltose concentrations (0–520 mM) were irradiated using 6 MV and 10 MV photon beams. Absorbance-dose response curves were plotted, and sensitivities were compared using regression analysis and ANOVA. Results indicated a significant difference in sensitivity between the two photon energies (p < 0.05), suggesting photon energy dependence in the evaluated HEMA PGDs. These findings emphasize the need for energy-specific calibration when using HEMA PGDs in clinical applications.

FUDMA Journal of SciencesVol. 9
Federal University Dutsin-Ma
Openalex Percentile: Top 87%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.