Establishing local diagnostic reference levels for adult whole-body PET/CT in Malaysia

The administered activity of 18F-FDG, 68Ga-PSMA, and 68Ga-DOTATATE examinations can be reduced without compromising or affecting the image quality. The proposed LDRL values for the CT parameters of the whole-body 18F-FDG examinations were the lowest among all compared values, but 68Ga-PSMA and 68Ga-DOTATATE examinations require further studies to optimize patient radiation doses in Malaysia and other regions while maintaining image quality.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2025-04-25
DOI
https://doi.org/10.1093/rpd/ncaf053
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishing local diagnostic reference levels for adult whole-body PET/CT in Malaysia

Ammar A. Oglat, Fatin Nadhirah binti A Halim, Laith Albadarneh, H. H. Saleh et al.
2 citations
Radiation Protection Dosimetry
Medical Imaging Techniques and Applications
2.72
article

Establishing local diagnostic reference levels for adult whole-body PET/CT in Malaysia

Ammar A. Oglat, Fatin Nadhirah binti A Halim, Laith Albadarneh, H. H. Saleh, Azhar Abdul Rahman, Abdallah Al Said, Wesal Shloul, Yahya Alshloul
article en
2 citations

Abstract

The administered activity of 18F-FDG, 68Ga-PSMA, and 68Ga-DOTATATE examinations can be reduced without compromising or affecting the image quality. The proposed LDRL values for the CT parameters of the whole-body 18F-FDG examinations were the lowest among all compared values, but 68Ga-PSMA and 68Ga-DOTATATE examinations require further studies to optimize patient radiation doses in Malaysia and other regions while maintaining image quality.

Radiation Protection DosimetryVol. 201(8)
Al-Hussein Bin Talal University (JO), Universiti Sains Malaysia (MY), Hashemite University (JO), Al al-Bayt University (JO), Yarmouk University (JO)
Openalex Percentile: Top 11%
Medical Imaging Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Establishing local diagnostic reference levels for adult whole-body PET/CT in Malaysia — Ammar A. Oglat, Fatin Nadhirah binti A Halim, et al. · Radiation Protection Dosimetry (2025) | TGRS Research Map | TGRS