The Early Experience of Synchrony in Ultra-Hypofractionation for Prostate Cancer: A Case Series

Ultra-hypofractionated radiotherapy has emerged as an effective treatment for localized prostate cancer, offering comparable oncologic outcomes to conventional fractionation while significantly reducing treatment duration. However, the delivery of high doses per fraction demands exceptional precision to minimize toxicity risks, particularly in the context of intrafractional prostate motion. Real-time tracking systems, such as Synchrony (Accuray, Sunnyvale, CA, USA), aim to address this challenge by continuously monitoring and correcting for target displacement during beam delivery. This study evaluates the technical feasibility and early clinical outcomes of ultra-hypofractionated radiotherapy (36.25 Gy in five fractions) delivered with Synchrony real-time tracking, with specific analysis of prostate specific antigen (PSA) kinetics, treatment delivery parameters, and safety. Five consecutive patients received fiducial-based radiotherapy with continuous motion tracking. PSA levels were monitored during the first two months post-treatment. Treatment efficiency metrics (including beam interruptions and motion events) and acute toxicity (Common Terminology Criteria for Adverse Events (CTCAE) v5.0) were prospectively recorded. A rapid biochemical response was observed, with a mean PSA decline rate of -4.27 ng/mL/month. System performance demonstrated stable rigid-body tracking with a median deviation of 1.04 mm (IQR: 0.74 to 1.39 mm), and clinically acceptable posterior displacement in the Z-axis with a median of -1.54 mm (IQR: -2.80 to -0.38 mm). The composite 3D target offset had a median of 2.52 mm (IQR: 1.53 to 3.30 mm). Automatic pauses occurred when motion exceeded safety thresholds, increasing mean treatment duration by 13.9% (actual: 586.5 seconds vs. planned: 514.9 seconds). Despite systematic posterior tracking offsets, toxicity was minimal (one grade 1 GI event). Synchrony tracking enabled precise ultra-hypofractionated delivery with submillimeter accuracy and minimal toxicity. The modest increase in treatment time is a justifiable trade-off for real-time motion adaptation. These early results support further investigation into Synchrony-optimized prostate ultra-hypofractionated radiotherapy.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-05-18
DOI
https://doi.org/10.7759/cureus.84323
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Early Experience of Synchrony in Ultra-Hypofractionation for Prostate Cancer: A Case Series

Anirut Watcharawipha, Wannapha Nobnop, Anupong Kongsa, Ekkasit Tharavichitkul et al.
1 links
Cureus
Prostate Cancer Diagnosis and Treatment
article

The Early Experience of Synchrony in Ultra-Hypofractionation for Prostate Cancer: A Case Series

Anirut Watcharawipha, Wannapha Nobnop, Anupong Kongsa, Ekkasit Tharavichitkul, Pooriwat Muangwong, Piyapasara Toapichattrakul
article en

Abstract

Ultra-hypofractionated radiotherapy has emerged as an effective treatment for localized prostate cancer, offering comparable oncologic outcomes to conventional fractionation while significantly reducing treatment duration. However, the delivery of high doses per fraction demands exceptional precision to minimize toxicity risks, particularly in the context of intrafractional prostate motion. Real-time tracking systems, such as Synchrony (Accuray, Sunnyvale, CA, USA), aim to address this challenge by continuously monitoring and correcting for target displacement during beam delivery. This study evaluates the technical feasibility and early clinical outcomes of ultra-hypofractionated radiotherapy (36.25 Gy in five fractions) delivered with Synchrony real-time tracking, with specific analysis of prostate specific antigen (PSA) kinetics, treatment delivery parameters, and safety. Five consecutive patients received fiducial-based radiotherapy with continuous motion tracking. PSA levels were monitored during the first two months post-treatment. Treatment efficiency metrics (including beam interruptions and motion events) and acute toxicity (Common Terminology Criteria for Adverse Events (CTCAE) v5.0) were prospectively recorded. A rapid biochemical response was observed, with a mean PSA decline rate of -4.27 ng/mL/month. System performance demonstrated stable rigid-body tracking with a median deviation of 1.04 mm (IQR: 0.74 to 1.39 mm), and clinically acceptable posterior displacement in the Z-axis with a median of -1.54 mm (IQR: -2.80 to -0.38 mm). The composite 3D target offset had a median of 2.52 mm (IQR: 1.53 to 3.30 mm). Automatic pauses occurred when motion exceeded safety thresholds, increasing mean treatment duration by 13.9% (actual: 586.5 seconds vs. planned: 514.9 seconds). Despite systematic posterior tracking offsets, toxicity was minimal (one grade 1 GI event). Synchrony tracking enabled precise ultra-hypofractionated delivery with submillimeter accuracy and minimal toxicity. The modest increase in treatment time is a justifiable trade-off for real-time motion adaptation. These early results support further investigation into Synchrony-optimized prostate ultra-hypofractionated radiotherapy.

CureusVol. 17(5)
Chiang Mai University (TH)
Gender equality
Openalex Percentile: Top 82%
Prostate Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.