Improving SpO <sub>2</sub> estimation accuracy under varying respiratory intensities using whale optimization and Gaussian process regression

Accurate and continuous monitoring of oxygen saturation (SpO<sub>2</sub>) is critical for managing respiratory disorders. This study investigates the influence of varying respiratory intensities on SpO<sub>2</sub> estimation and proposes an optimized predictive model to enhance accuracy. Photoplethysmography (PPG) signals were collected using a controlled laboratory simulator across SpO<sub>2</sub> levels ranging from 80% to 100% under six distinct respiratory intensity levels, generating a dataset of 12,250 signal segments. To improve estimation performance, a Gaussian Process Regression (GPR) model was developed, with its hyperparameters optimized using five distinct algorithms: Bayesian Optimization (BO), Genetic Algorithm (GA), Whale Optimization Algorithm (WOA), Grey Wolf Optimizer (GWO), and Particle Swarm Optimization (PSO). These optimization techniques were selected to encompass diverse computational paradigms, including probabilistic modeling, evolutionary strategies, and swarm intelligence, ensuring a robust comparative evaluation. Experimental results demonstrated that the WOA-optimized GPR (WOA-GPR) model exhibited superior performance across varying respiratory conditions, achieving a Mean Absolute Error (MAE) between 0.89 and 1.41 and a Root Mean Square Error (RMSE) between 0.63 and 0.86. Comparative analysis against other regression models, including Support Vector Regression (SVR) and Random Forest Regression (RFR), further confirmed the effectiveness of the WOA-GPR model. Finally, validation using real-world physiological data reinforced its reliability for practical applications. These findings underscore the potential of WOA-GPR as a promising approach for enhancing real-time SpO<sub>2</sub> estimation in health monitoring applications.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-05-17
DOI
https://doi.org/10.1080/10255842.2025.2504160
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving SpO 2 estimation accuracy under varying respiratory intensities using whale optimization and Gaussian process regression

Jing Jiang, Xinjie Feng, Xinchen Yu, Xiaobing Zuo et al.
Computer Methods in Biomechanics & Biomedical Engineering
Non-Invasive Vital Sign Monitoring
article

Improving SpO 2 estimation accuracy under varying respiratory intensities using whale optimization and Gaussian process regression

Jing Jiang, Xinjie Feng, Xinchen Yu, Xiaobing Zuo, Min Li
article en

Abstract

Accurate and continuous monitoring of oxygen saturation (SpO<sub>2</sub>) is critical for managing respiratory disorders. This study investigates the influence of varying respiratory intensities on SpO<sub>2</sub> estimation and proposes an optimized predictive model to enhance accuracy. Photoplethysmography (PPG) signals were collected using a controlled laboratory simulator across SpO<sub>2</sub> levels ranging from 80% to 100% under six distinct respiratory intensity levels, generating a dataset of 12,250 signal segments. To improve estimation performance, a Gaussian Process Regression (GPR) model was developed, with its hyperparameters optimized using five distinct algorithms: Bayesian Optimization (BO), Genetic Algorithm (GA), Whale Optimization Algorithm (WOA), Grey Wolf Optimizer (GWO), and Particle Swarm Optimization (PSO). These optimization techniques were selected to encompass diverse computational paradigms, including probabilistic modeling, evolutionary strategies, and swarm intelligence, ensuring a robust comparative evaluation. Experimental results demonstrated that the WOA-optimized GPR (WOA-GPR) model exhibited superior performance across varying respiratory conditions, achieving a Mean Absolute Error (MAE) between 0.89 and 1.41 and a Root Mean Square Error (RMSE) between 0.63 and 0.86. Comparative analysis against other regression models, including Support Vector Regression (SVR) and Random Forest Regression (RFR), further confirmed the effectiveness of the WOA-GPR model. Finally, validation using real-world physiological data reinforced its reliability for practical applications. These findings underscore the potential of WOA-GPR as a promising approach for enhancing real-time SpO<sub>2</sub> estimation in health monitoring applications.

Computer Methods in Biomechanics & Biomedical Engineering
Shanghai University (CN)
Shanghai University
Life below water
Openalex Percentile: Top 90%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.