Computational study on the integration of a piezoelectric element into an uncemented revision hip stem for energy supply of smart implant functions

In the future, self-powered smart hip implants may enhance the longevity of total hip replacements. Uncemented hip stems aim to promote integration within the bone stock through electrical bone stimulation before loosening occurs, necessitating an internal energy source. Piezoelectric energy harvesting presents a viable solution. This study aimed to integrate a piezoelectric element into an uncemented revision hip stem in a manner that maximizes electrical output while preserving mechanical stability of the implant. Finite element (FE) analysis was used to evaluate cavities of varying sizes, based on the integrated piezoelectric element, and different positions in the medial neck area of the hip stem. An FE model with physiological boundary conditions during gait assessed the electrical power output, while a separate static FE model, based on ISO 7206-4, analyzed mechanical stress distribution and fatigue resistance of the implant. The most promising design was selected for endurance testing per ISO 7206-4. For the optimal design, the maximum stress was 315 MPa, with a fatigue life of >10<sup>9</sup> cycles and a safety factor of 2.01 according to Soderberg criteria. The design successfully passed the ISO 7206-4 endurance test and achieved a calculated average electrical power output of 439 μW during gait. In conclusion, an uncemented revision hip stem can be modified to incorporate a piezoelectric element for energy conversion. Future work will focus on experimental evaluation of the electrical voltage and power generation during physiological activities.

Authors

Institutions

Publication Details

Journal
Computers in Biology and Medicine
Published
2025-05-17
DOI
https://doi.org/10.1016/j.compbiomed.2025.110264
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational study on the integration of a piezoelectric element into an uncemented revision hip stem for energy supply of smart implant functions

Franziska Geiger, Pia Kloubert, Daniel Kluess, Rainer Bader
Computers in Biology and Medicine
Orthopaedic implants and arthroplasty
article

Computational study on the integration of a piezoelectric element into an uncemented revision hip stem for energy supply of smart implant functions

Franziska Geiger, Pia Kloubert, Daniel Kluess, Rainer Bader
article en

Abstract

In the future, self-powered smart hip implants may enhance the longevity of total hip replacements. Uncemented hip stems aim to promote integration within the bone stock through electrical bone stimulation before loosening occurs, necessitating an internal energy source. Piezoelectric energy harvesting presents a viable solution. This study aimed to integrate a piezoelectric element into an uncemented revision hip stem in a manner that maximizes electrical output while preserving mechanical stability of the implant. Finite element (FE) analysis was used to evaluate cavities of varying sizes, based on the integrated piezoelectric element, and different positions in the medial neck area of the hip stem. An FE model with physiological boundary conditions during gait assessed the electrical power output, while a separate static FE model, based on ISO 7206-4, analyzed mechanical stress distribution and fatigue resistance of the implant. The most promising design was selected for endurance testing per ISO 7206-4. For the optimal design, the maximum stress was 315 MPa, with a fatigue life of >10<sup>9</sup> cycles and a safety factor of 2.01 according to Soderberg criteria. The design successfully passed the ISO 7206-4 endurance test and achieved a calculated average electrical power output of 439 μW during gait. In conclusion, an uncemented revision hip stem can be modified to incorporate a piezoelectric element for energy conversion. Future work will focus on experimental evaluation of the electrical voltage and power generation during physiological activities.

Computers in Biology and MedicineVol. 192(Pt B)
University of Rostock (DE)
Deutsche Forschungsgemeinschaft
Affordable and clean energy
Openalex Percentile: Top 81%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.