Residual tensile strength of GFRP bars after exposure to sustained loads and harsh laboratory and field environmental conditions

This paper investigates the tensile strength of glass fiber-reinforced polymer (GFRP) bars embedded in concrete under harsh environmental conditions and sustained loads. A total of 135 specimens were constructed for this investigation, each consisting of a 1.3 m length of GFRP bar centrally embedded in a concrete prism. After casting and curing, the specimens were exposed to a tensile stress that is 25% of their maximum tensile strength. The specimens were then exposed to six accelerated laboratory conditions for 6, 12, and 18 months, along with a controlled environment in the laboratory. The test conditions involved exposure to both seawater and tap water at temperatures of 23°C and 50°C, alternating wet/dry cycles in seawater at 50°C, and immersion in an alkaline solution maintained at 50°C. Moreover, two harsh field conditions (hot dry and hot humid) were also considered. GFRP bars’ performance was assessed through tensile strength tests. The results indicated that after the exposure of 18 months, the maximum tensile strength loss occurred in bars exposed to environments of tap water and alkaline solution at the temperatures of 50°C with 18.2 and 16.8% strength losses, respectively. Conversely, the two field conditions did not significantly affect the residual strength of the GFRP bars. The test results revealed that the sustained load alone increased the strength losses by an average of 6.4% with a minimum of 1.3% in the environment of seawater at room temperature and a maximum of 11.4% in the seawater (wet/dry cycles) at 50°C after 18 months.

Authors

Institutions

Publication Details

Journal
Journal of Composite Materials
Published
2025-05-17
DOI
https://doi.org/10.1177/00219983251340561
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
1.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Residual tensile strength of GFRP bars after exposure to sustained loads and harsh laboratory and field environmental conditions

Yousef Al-Salloum, Tarek H Almusallam, Sherif El-Gamal, Saleh H. Alsayed et al.
1 citations
Journal of Composite Materials
Structural Behavior of Reinforced Concrete
1.01
article

Residual tensile strength of GFRP bars after exposure to sustained loads and harsh laboratory and field environmental conditions

Yousef Al-Salloum, Tarek H Almusallam, Sherif El-Gamal, Saleh H. Alsayed, Salma El-Maghawri
article en
1 citations

Abstract

This paper investigates the tensile strength of glass fiber-reinforced polymer (GFRP) bars embedded in concrete under harsh environmental conditions and sustained loads. A total of 135 specimens were constructed for this investigation, each consisting of a 1.3 m length of GFRP bar centrally embedded in a concrete prism. After casting and curing, the specimens were exposed to a tensile stress that is 25% of their maximum tensile strength. The specimens were then exposed to six accelerated laboratory conditions for 6, 12, and 18 months, along with a controlled environment in the laboratory. The test conditions involved exposure to both seawater and tap water at temperatures of 23°C and 50°C, alternating wet/dry cycles in seawater at 50°C, and immersion in an alkaline solution maintained at 50°C. Moreover, two harsh field conditions (hot dry and hot humid) were also considered. GFRP bars’ performance was assessed through tensile strength tests. The results indicated that after the exposure of 18 months, the maximum tensile strength loss occurred in bars exposed to environments of tap water and alkaline solution at the temperatures of 50°C with 18.2 and 16.8% strength losses, respectively. Conversely, the two field conditions did not significantly affect the residual strength of the GFRP bars. The test results revealed that the sustained load alone increased the strength losses by an average of 6.4% with a minimum of 1.3% in the environment of seawater at room temperature and a maximum of 11.4% in the seawater (wet/dry cycles) at 50°C after 18 months.

Journal of Composite MaterialsVol. 59(27)
King Saud University (SA), Sultan Qaboos University (OM)
Openalex Percentile: Top 25%
Structural Behavior of Reinforced Concrete
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.