Performance evaluation of plate heat exchangers with chevron-type corrugation pattern for the superfluid helium cryogenic system

The 2 K heat exchanger is a critical component of the superfluid helium cryogenic system. In this paper, to further reduce the volume and manufacturing cost, a plate heat exchanger (PHE) with herringbone corrugation was innovatively used as a 2K heat exchanger. The CFD numerical method was used to simulate the single flow channel of the PHE with chevron-type corrugation pattern. It got correlations of Colburn factor j , Fanning friction factor f with Reynolds number in the core part and empirical correlations of pressure drop in the fluid distribution parts. A PHE prototype was designed based on the distributed parameter differential method and correlations. Meanwhile, the 2K cryogenic test was carried out on the PHE prototype using supercritical helium and liquid helium respectively. The results show that the calculated values are in good agreement with experimental ones. The PHE design method is simple and accurate based on distributed parameter method and CFD in this study. And brazed PHEs can be used in the liquid helium temperature range.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-05-17
DOI
https://doi.org/10.1016/j.csite.2025.106359
Citations
2
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of plate heat exchangers with chevron-type corrugation pattern for the superfluid helium cryogenic system

Dajun Fan, Yongping Hu, Xiaofei Niu, Yugang Zhao et al.
2 citations
Case Studies in Thermal Engineering
Heat Transfer and Optimization
1.43
article

Performance evaluation of plate heat exchangers with chevron-type corrugation pattern for the superfluid helium cryogenic system

Dajun Fan, Yongping Hu, Xiaofei Niu, Yugang Zhao, Junhui Zhang, Peng Zhang, Li Zhu, Jun Wen, Xianjin Wang, Yu‐Xuan Wang
article en
2 citations

Abstract

The 2 K heat exchanger is a critical component of the superfluid helium cryogenic system. In this paper, to further reduce the volume and manufacturing cost, a plate heat exchanger (PHE) with herringbone corrugation was innovatively used as a 2K heat exchanger. The CFD numerical method was used to simulate the single flow channel of the PHE with chevron-type corrugation pattern. It got correlations of Colburn factor j , Fanning friction factor f with Reynolds number in the core part and empirical correlations of pressure drop in the fluid distribution parts. A PHE prototype was designed based on the distributed parameter differential method and correlations. Meanwhile, the 2K cryogenic test was carried out on the PHE prototype using supercritical helium and liquid helium respectively. The results show that the calculated values are in good agreement with experimental ones. The PHE design method is simple and accurate based on distributed parameter method and CFD in this study. And brazed PHEs can be used in the liquid helium temperature range.

Case Studies in Thermal EngineeringVol. 72
Chinese Academy of Sciences (CN), Institute of Modern Physics (CN), University of Chinese Academy of Sciences (CN), Lanzhou University (CN)
Affordable and clean energy
Openalex Percentile: Top 20%
Heat Transfer and Optimization
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.