Experimental investigation of spray cooling on steel plates with periodic micropillar structures: Two-stage quenching phenomenon

• Transient spray cooling of micropillared surfaces showed novel two-stage quenching. • Temperature drops within a pillar induced a first quench at the tip. • Secondary quench occurred when the wetting front reached the bottom of the pillars. In this study, water spray cooling tests were conducted on stainless steel samples with micropillars fabricated using a laser texturing method. The micropillars had a fixed pitch of 100 µm and varied in width (10–80 µm) and height (30–150 µm). The experiments revealed two distinct stages of quenching, observed as abrupt increases in the heat transfer rate during cooling from 700 °C to 100 °C on the micropillared samples. The first quench occurred at temperatures above 400 °C, as evaluated at the base of the pillars based on thermocouple readings, and was followed by a second quench at approximately 280 °C. The first quench was attributed to the onset of stable liquid–solid contact on the tops of the micropillars, enabled by significant temperature drops within the pillars. The wetting front subsequently advanced from the pillar tips to their bases, eventually covering the entire surface and resulting in the second quenching event. Taller micropillars were found to increase the “apparent” first quench temperature due to the longer heat conduction path through the pillars, which allowed stable wetting at the tips while maintaining higher temperatures at the bases. In contrast, shorter micropillars exhibited a gradual increase in cooling rate without a distinct first quench point. Increasing the micropillar width up to 30 µm (for a height of 50 µm) improved cooling performance due to the enhanced heat transfer area at the pillar tips. However, further increasing the width led to diminished performance, with heat transfer characteristics resembling those of a smooth sample. The second quench consistently occurred at approximately 280 °C, similar to the smooth sample, regardless of the pillar geometry.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2025-05-17
DOI
https://doi.org/10.1016/j.applthermaleng.2025.126870
Citations
4
Primary Topic
Fluid Dynamics and Heat Transfer
Type
article
Field-Weighted Citation Impact
5.34

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation of spray cooling on steel plates with periodic micropillar structures: Two-stage quenching phenomenon

Yutaku Kita, Hiroyuki Fukuda, Masamichi Kohno, Yasuyuki Takata et al.
4 citations
Applied Thermal Engineering
Fluid Dynamics and Heat Transfer
5.34
article

Experimental investigation of spray cooling on steel plates with periodic micropillar structures: Two-stage quenching phenomenon

Yutaku Kita, Hiroyuki Fukuda, Masamichi Kohno, Yasuyuki Takata, Takaaki Ariyoshi
article en
4 citations

Abstract

• Transient spray cooling of micropillared surfaces showed novel two-stage quenching. • Temperature drops within a pillar induced a first quench at the tip. • Secondary quench occurred when the wetting front reached the bottom of the pillars. In this study, water spray cooling tests were conducted on stainless steel samples with micropillars fabricated using a laser texturing method. The micropillars had a fixed pitch of 100 µm and varied in width (10–80 µm) and height (30–150 µm). The experiments revealed two distinct stages of quenching, observed as abrupt increases in the heat transfer rate during cooling from 700 °C to 100 °C on the micropillared samples. The first quench occurred at temperatures above 400 °C, as evaluated at the base of the pillars based on thermocouple readings, and was followed by a second quench at approximately 280 °C. The first quench was attributed to the onset of stable liquid–solid contact on the tops of the micropillars, enabled by significant temperature drops within the pillars. The wetting front subsequently advanced from the pillar tips to their bases, eventually covering the entire surface and resulting in the second quenching event. Taller micropillars were found to increase the “apparent” first quench temperature due to the longer heat conduction path through the pillars, which allowed stable wetting at the tips while maintaining higher temperatures at the bases. In contrast, shorter micropillars exhibited a gradual increase in cooling rate without a distinct first quench point. Increasing the micropillar width up to 30 µm (for a height of 50 µm) improved cooling performance due to the enhanced heat transfer area at the pillar tips. However, further increasing the width led to diminished performance, with heat transfer characteristics resembling those of a smooth sample. The second quench consistently occurred at approximately 280 °C, similar to the smooth sample, regardless of the pillar geometry.

Applied Thermal EngineeringVol. 275
Kyushu University (JP), King's College London (GB), Fukuyama University (JP)
Saga University, Japan Society for the Promotion of Science
Openalex Percentile: Top 4%
Fluid Dynamics and Heat Transfer
5.34
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.