The paper considers the process of examining the current state of materials and load-bearing structures of an old building. Such buildings are often located in a forest complex. Recommendations to eliminate the defects and damage identified as a result of the survey, as well as the possibility of increasing the number of storeys were made. The process of examining the main part of the building, which is complex in terms of shape and is under the influence of the external environment of the forest complex, is considered. The design feature of the building is studied. The results of visual and instrumental inspection of the building are presented. The main recommendations for the elimination of defects and damages are developed and given. It is noted that the technical examination of the old building by the method of non-destructive testing showed that the state of the building structures of the building at the time of the survey was limited in working capacity.

Authors

Institutions

Publication Details

Journal
E3S Web of Conferences
Published
2025-01-01
DOI
https://doi.org/10.1051/e3sconf/202562705006
Primary Topic
Geodetic Measurements and Engineering Structures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostics of the technical condition of load-bearing structures of an old building

Irina Shcherbakova, S. Nikolenko, Светлана Сазонова, Eduard Chernikov et al.
E3S Web of Conferences
Geodetic Measurements and Engineering Structures
article

Diagnostics of the technical condition of load-bearing structures of an old building

Irina Shcherbakova, S. Nikolenko, Светлана Сазонова, Eduard Chernikov, Evgeny Anikeev
article en

Abstract

The paper considers the process of examining the current state of materials and load-bearing structures of an old building. Such buildings are often located in a forest complex. Recommendations to eliminate the defects and damage identified as a result of the survey, as well as the possibility of increasing the number of storeys were made. The process of examining the main part of the building, which is complex in terms of shape and is under the influence of the external environment of the forest complex, is considered. The design feature of the building is studied. The results of visual and instrumental inspection of the building are presented. The main recommendations for the elimination of defects and damages are developed and given. It is noted that the technical examination of the old building by the method of non-destructive testing showed that the state of the building structures of the building at the time of the survey was limited in working capacity.

E3S Web of ConferencesVol. 627
Voronezh State University of Forestry and Technologies (RU), Voronezh State Technical University (RU), Voronezh State University (RU)
Openalex Percentile: Top 89%
Geodetic Measurements and Engineering Structures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.